Table 7.3
Other BIOS Error Messages (Cont.)
Message
Unresolved
configuration
mismatch between
disks and NVRAM on
the adapter
7.4

Other Potential Problems

Table 7.4
Other Potential Problems
Topic
DOS ASPI
CD drives under
DOS
Physical drive errors To display the MegaRAID Manager Media Error and Other Error options, select
Virtual sizing
BSD Unix
Multiple LUNs
Problem
The configuration stored in the
MegaRAID NVRAM does not
match the configuration stored
on the drives.
Table 7.4
describes other potential problems.
Information
MEGASPI.SYS, the MegaRAID DOS ASPI manager, uses 6 Kbytes of system
memory once it is loaded.
At this time, copied CDs are not accessible from DOS even after loading
MEGASPI.SYS and MEGACDR.SYS.
the Objects menu, then Physical Drive. Select a physical drive and press <F2>.
The windows displays the number of errors.
A Media Error is an error that occurred while actually transferring data. An
Other Error is an error that occurs at the hardware level because of a device
failure, poor cabling, bad termination, signal loss, etc.
The virtual sizing option enables RAID expansion. Virtual sizing must be
enabled to increase the size of a logical drive or add a physical drive to an
existing logical drive.
Run the BIOS Configuration Utility by pressing <Ctrl><M> to enable virtual
sizing. Select Objects, then Logical Drive. Next, select View/Update
Parameters, then set Virtual Sizing to Enabled.
We do not provide a driver for BSDI Unix. MegaRAID SCSI 320-1 does not
support BSDI Unix.
MegaRAID SCSI 320-1 supports one logical unit number (LUN) per each target
ID. No multiple LUN devices are supported.
Other Potential Problems
Copyright © 2002 by LSI Logic Corporation. All rights reserved.
Suggested Solution
1. Press a key to run MegaRAID Manager.
2. Select View/Add Configuration from the
Configure menu.
3. Use View/Add Configuration to examine
both the configuration in NVRAM and the
configuration stored on the disk drives.
4. Resolve the problem by selecting one of
the configurations.
7-5