2.3.12 Logical Drive States

2.3.13 SCSI Drive States

2-10
The MegaRAID SCSI 320-1 rebuild rate can be configured between 0%
and 100%. At 0%, the rebuild is only done if the system is not doing
anything else. At 100%, the rebuild has a higher priority than any other
system activity.
Table 2.2
describes the logical drive states.
Table 2.2
Logical Drive States
State
Description
Optimal
The drive operating condition is good. All configured drives are
online.
Degraded
The drive operating condition is not optimal. One of the
configured drives has failed or is offline.
Failed
The drive has failed.
Offline
The drive is not available to MegaRAID SCSI 320-1.
A SCSI disk drive can be in one of the states described in
Table 2.3
SCSI Drive States
State
Description
Online
The drive is functioning normally and is a part of a configured
(ONLIN)
logical drive.
Ready
The drive is functioning normally but is not part of a configured
(READY)
logical drive and is not designated as a hot spare.
Hot Spare
The drive is powered up and ready for use as a spare in case an
(HOTSP)
online drive fails.
Fail
A fault has occurred in the drive, placing it out of service.
(FAIL)
Rebuild
The drive is being rebuilt with data from a failed drive.
(REB)