Other Bios Error Messages - LSI MegaRAID SCSI 320-1 RAID Controller Series 520 Hardware Manual

Raid controller
Table of Contents

Advertisement

Table 7.2
BIOS Boot Error Messages (Cont.)
Message
1 Logical Drive
Degraded
The following SCSI IDs
are not responding:
Channel x:a.b.c
7.3

Other BIOS Error Messages

Table 7.3
Other BIOS Error Messages
Message
Following SCSI disk
not found and no
empty slot available
for mapping it
Following SCSI IDs
have the same data y,
z
Channel x: a, b, c
7-4
Problem
A logical drive signed on
in a degraded state.
The physical drives with
SCSI IDs a, b, and c are
not responding on SCSI
channel x.
Table 7.3
describes other BIOS error messages, their meaning, and
suggested solutions.
Problem
The physical disk roaming
feature did not find the
physical disk with the
displayed SCSI ID. No slot is
available to map the physical
drive. MegaRAID cannot
resolve the physical drives
into the current configuration.
The physical drive roaming
feature found the same data
on two or more physical drive
on channel x with SCSI IDs a,
b, and c. MegaRAID cannot
determine the drive that has
the duplicate information.
Troubleshooting
Copyright © 2002 by LSI Logic Corporation. All rights reserved.
Suggested Solution
Make sure all physical drives are properly
connected and are powered on.
Run MegaRAID Manager to find out if any
physical drives are not responding. Reconnect,
replace, or rebuild any drive that is not
responding.
Make sure the physical drives are properly
connected and are powered on.
Suggested Solution
Reconfigure the array.
Remove the drive or drives that should not
be used.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Megaraid scsi 320-1

Table of Contents