Further details regarding the individual steps
A
A Shut-off valve
B Drain valve
C Fill valve
1. Open shut-off tap or valves.
Note
With the Solar-Divicon, open the non-
return valves by turning the thermom-
eters clockwise through 45°.
2. Close shut-off valve A.
3. Open drain valve B and fill
valve C.
P
E
C
F
B
Commissioning, inspection, maintenance
(cont.)
D
D Container for heat transfer medium
E Pressure gauge
F Fill pump
4. Connect hoses from the flushing and
filling facility. Fill the container with
heat transfer medium.
Note
Flush the system via the return con-
nection (flow direction to the collec-
tor).
Use a high speed pump for this pur-
pose.