Lamp Unit - Fujitsu M3099EX Reference Manual

Image scanner
Hide thumbs Also See for M3099EX:
Table of Contents

Advertisement

Never replace the lamp without turning off the power.
Wait at least 3 minutes after turning off the power before touching the lamp.
Wechseln Sie niemals die Lampe ohne den Scanner auszuschalten.
Warten Sie mindestens 3 Minuten nach Ausschalten, bevor Sie die Lampe anfassen.
Insert a fingernail at the end
5
of the heater to separate it
from the lamp.
CAUTION
• Do not pull the heater wire.
• Do not remove the tape from the heater.
Re-install the lamp unit using the
8
two grooves (
plate ( ).
Tighten the thumb screw and re-
9
insall the side cover.
If the thumb screw is loose, the
error message "COVER OPEN"
may appear.
WARNING
ACHTUNG
and
) and guide
Heater
Heater
Attach a new lamp to the heater.
6
Be sure to face the clear portion of
the lamp up and center the lamp in
the heater, otherwise black stripes
may appear in the image on the
display.
Insert the terminals of the lamp
7
into the socket and rotate until the
clear portion faces up.
Lamp

Lamp unit

3-3