Never replace the lamp without turning off the power.
Wait at least 3 minutes after turning off the power before touching the lamp.
Wechseln Sie niemals die Lampe ohne den Scanner auszuschalten.
Warten Sie mindestens 3 Minuten nach Ausschalten, bevor Sie die Lampe anfassen.
Insert a fingernail at the end of the
4
heater to separate it from the
lamp.
CAUTION
• Do not pull the heater wire.
• Do not remove the tape from the heater.
• When you re-clamp the right bracket, do
not pinch the heater cable.
(yellow/black 4 cables)
Attach a new lamp to the heater.
5
Be sure to face the clear portion
of the lamp up and center the
lamp in the heater, otherwise
black stripes may appear in the
image of the document.
○
○
○
○
○
○
○
○
○
○
○
○
WARNING
ACHTUNG
○
○
○
○
○
○
○
○
○
○
○
○
○
Heater
Heater
○
○
○
○
○
○
○
○
○
○
○
○
○
Insert the terminals of the lamp into
6
the sockets and rotate until the
clear portion faces down.
Align the two socket covers and
7
snap them on to the ends.
8
Close the upper transport unit.
Lamp socket cover
Lamp
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
3-5