Never replace the lamp without turning off the power.
Wait at least 3 minutes after turning off the power before touching the lamp.
Wechseln Sie niemals die Lampe ohne den Scanner auszuschalten.
Warten Sie mindestens 3 Minuten nach Ausschalten, bevor Sie die Lampe anfassen.
Insert a fingernail at the end of the
4
heater to separate it from the
lamp.
CAUTION
• Do not pull the heater wire.
• Do not remove the tape from the heater.
• When you re-clamp the right bracket, do
not pinch the heater cable.
(yellow/black 4 cables)
Attach a new lamp to the heater.
5
Be sure to face the clear portion
of the lamp up and center the
lamp in the heater, otherwise
black stripes may appear in the
image of the document.
WARNING
ACHTUNG
Heater
Heater
Insert the terminals of the lamp into
6
the sockets and rotate until the
clear portion faces down.
Align the two socket covers and
7
snap them on to the ends.
8
Close the upper transport unit.
Lamp socket cover