7.4.3 Replacing the oil filter

Perform maintenance op-
erations only with the motor off.
To clean the motor oil filter cartridge, you must
remove it.
Unscrew the sealing cap (Fig. 20 ref. 1).
Remuve filter (Fig. 20 ref. 2).
Scalding hazard due to
boiling oil. Recover the used oil and dispose
of it without polluting the environment, ac-
cording to current laws.
Clean the oil filter cartridge using compressed air
to blow from inside out.
Make sure the sealing ring (Fig. 20 ref. 3) has not
been damaged, and is firmly in place.
Make sure the sealing ring (Fig. 20 ref. 4) has not
been damaged, and is firmly in place. Change
the oil filter if necessary.
Use oil to lubricate the sealing before fitting a
new cartridge.
Reassemble and refit oil filter.
Service the oil filter every
500 working hours.
14
GB
8
INSTRUCTIONS ON PUTTING OUT OF
WORK AND DISMANTLING

8.2 Dismantling

Decommissioning / dismantling of the generator
set should only be undertaken by specialist wor-
kshops.

9 FIRE - IN CASE OF

In case of fire, never open the hood of the gener-
ating set and use only approved type fire extin-
guishers.
out flames in the generating unit.
Electronic control panel connector
WHITE
GREY
PURPLE
BLUE
GREEN
YELLOW
ORANGE
RED
BROWN
20
Energy 4004 D
Never use water to put
ORANGE
BLACK
RED
WHITE
BLUE
YELLOW
PINK
GREY
GREEN
GENERATOR
Vers. 007