Commands Function
R CR LF
Reset to manufacturer setting - reset
Command to call up the values of the balance
PC CR LF
Measuring value stable
S CR LF
Measuring value instable
SI CR LF
Last stable measuring value
SU CR LF
SU CR LF
Current measuring value
Zeroing stable value
Z CR LF
ZI CR LF
Zeroing instable value
Taring stable value
T CR LF
TI CR LF
Taring instable value
Cancel continuous data output
C0 CR LF
Start continuous data output
C1 CR LF
Cancel continuous data output (operating mode)
CU0 CR LF
Start continuous data output (operating mode)
CU1 CR LF
NB CR LF
Serial no. of balance
Weighing range max.
FS CR LF
RV CR LF
Software issue
Date display
PD CR LF
PD CR LF
Time display
Operating mode
PMCR LF
Balance parameters are printed out
PS CR LF
Tone
B CR LF
Call up error message
ER CR LF
DS CR LF
Display check
Delete display check
CS CR LF
DH CR LF
Display check header
Delete display check header
CH CR LF
DF CR LF
Display check bar graph (footer)
Delete display check bar graph (footer)
CF CR LF
Start internal adjustment from outside
CL CR LF
Lock keyboard
KL CR LF
Unlock keyboard
KU CR LF
E0 CR LF
Keytone off
Keytone on
E1 CR LF
O0 CR LF
Balance off
Balance on
O1 CR LF
A0 CR LF
Auto zero off
Auto zero on
A1 CR LF
Automatic adjustment off
TC0 CR LF
Automatic adjustment on
TC1 CR LF