 Uses the MATE3™ System Display and Controller or the AXS Port™ SunSpec Modbus Interface (sold
separately) for user interface as part of a Grid/Hybrid system
MATE3 must have firmware revision 003.002.xxx or higher
 Supports the OPTICS RE™ online tool
Requires the MATE3 or the AXS Port
Visit www.outbackpower.com to download
 Uses the HUB10.3™ Communications Manager for stacking as part of a Grid/Hybrid system
~
Stackable in series, parallel, series/parallel, and three-phase configurations
 Listed to UL 1741 (2
nd
Field-upgradeable firmware (from www.outbackpower.com); requires MATE3 or AXS Port
Seven selectable input modes for different applications
Generator
Support
Grid Tied (available in 24-volt and 48-models only)
UPS
Backup
Mini Grid
GridZero
Single AC input with dual input programming; individualized modes and priorities can be selected when
switching from utility grid to AC generator
external transfer device required
system display required for individual programming
NOTE : This product has a settable AC output range. In this book, many references to the output refer
to the entire range. However, some references are made to 120 Vac or 60 Hz output. These are
intended as examples only.

Inverter Controls

The FXR inverter has no external controls. It can operate normally without an external control or
interface. Basic modes and settings are pre-programmed at the factory. (See the menu tables
beginning on page 76.) However, external communication devices such as the OutBack MATE3 or
AXS Port can be used to operate or program the inverter.

MATE3 System Display and Controller

The MATE3 System Display and Controller (sold separately) is designed to accommodate
programming and monitoring of a Grid/Hybrid power system. The MATE3 provides the means to
adjust the factory default settings to correctly match the installation where needed. It provides the
means to monitor system performance and troubleshoot fault or shutdown conditions. It also has
data logging and interface functions using the Internet.
Once settings are modified using a MATE3, the MATE3 can be removed from the installation. The
settings are stored in the nonvolatile memory of the FXR inverter. However, it is highly recommended
1
Outback Power Technologies Intuitive Control System for Renewable Energy
900-0167-01-00 Rev A
1
for a cloud-based remote monitoring and control application