Outback FXR2012A Operator's Manual page 79

Fxr series inverter/charger
Table of Contents

Advertisement

Field
Aux Control
Aux Mode
(Load Shed) ON: Batt >
(Load Shed ON) Delay
(Load Shed) OFF: Batt <
(Load Shed OFF) Delay
(Gen Alert) ON: Batt <
(Gen Alert ON) Delay
(Gen Alert) OFF: Batt >
(Gen Alert OFF) Delay
Auxiliary Output
(Vent Fan) ON: Batt >
(Vent Fan) Off Delay
(DC Divert) ON: Batt >
(DC Divert ON) Delay
(DC Divert) OFF: Batt <
(DC Divert OFF) Delay
(AC Divert) ON: Batt >
(AC Divert ON) Delay
(AC Divert) OFF: Batt <
(AC Divert OFF) Delay
Inverter Stacking
Stack Mode
Power Save
Mode = Master:
Ranking
Mode = Slave:
Offset Enable
Grid-Tie Sell
Sell Voltage
AC Input Voltage
Calibrate
AC Output Voltage
Battery Voltage
Grid Interface Protection Menu
Operating Frequency
Operating Frequency
Stage 1 Voltage Trip
Over Voltage Clearance Time
Over Voltage Trip
Under Voltage Clearance Time
Under Voltage Trip
Stage 2 Voltage Trip
Over Voltage Clearance Time
Over Voltage Trip
Under Voltage Clearance Time
Under Voltage Trip
Frequency Trip
Over Frequency Clearance Time
Over
Frequency Trip
Under Frequency Clearance Time
Under
Frequency Trip
Clearance Time
Mains Loss
Reconnect Delay
Multi-Phase Coordination
Maximum Sell
Sell Current Limit
Current
Model Select
900-0167-01-00 Rev A
Table 24
FXR Settings for 24-Volt Models
Item
Master Power Save Level
Slave Power Save Level
60-Hz system
50-Hz system
60-Hz system
50-Hz system
Coordin. AC Connect/Disconn.
FXR2524A
VFXR3524A
Default
Minimum
Auto
Load Shed, Gen Alert, Fault, Vent Fan, Cool Fan,
Vent Fan
DC Divert, GT Limits, Source Status, AC Divert
28.0 Vdc
0.5 minutes
0.1 minutes
22.0 Vdc
0.5 minutes
0.1 minutes
22.0 Vdc
0.5 minutes
0.1 minutes
28.0 Vdc
0.5 minutes
0.1 minutes
28.0 Vdc
0.5 minutes
0.1 minutes
28.0 Vdc
0.5 minutes
0.1 minutes
22.0 Vdc
0.5 minutes
0.1 minutes
28.0 Vdc
0.5 minutes
0.1 minutes
22.0 Vdc
0.5 minutes
0.1 minutes
Master, Slave, L2 Phase Master, B Phase Master,
Master
0
1
Y
26.0 Vdc
0 Vac
X
0 Vac
X
0.0 Vdc
X
X
60 Hz
X
1.0 seconds
0.12 seconds
132 Vac
X
X
2.0 seconds
0.12 seconds
X
106 Vac
X
0.16 seconds
0.12 seconds
144 vac
X
X
0.16 seconds
0.12 seconds
X
60 Vac
X
0.16 seconds
0.12 seconds
60.5 Hz
X
50.5 Hz
X
0.16 seconds
0.12 seconds
59.3 Hz
X
49.3 Hz
2.0 seconds
1.0 seconds
X
300 seconds
2 seconds
X
N
20 Aac
X
20 Aac
X
Vented
Specifications
Maximum
Off, Auto or On
20.0 Vdc
36.0 Vdc
25.0 minutes
20.0 Vdc
36.0 Vdc
25.0 minutes
20.0 Vdc
36.0 Vdc
25.0 minutes
20.0 Vdc
36.0 Vdc
25.0 minutes
20.0 Vdc
36.0 Vdc
25.0 minutes
20.0 Vdc
36.0 Vdc
25.0 minutes
20.0 Vdc
36.0 Vdc
25.0 minutes
20.0 Vdc
36.0 Vdc
25.0 minutes
20.0 Vdc
36.0 Vdc
25.0 minutes
C Phase Master
0
10
1
10
Y or N
22.0 Vdc
32.0 Vdc
–7 Vac
7 Vac
–7 Vac
7 Vac
–0.4 Vdc
0.4 Vdc
50 Hz, 60 Hz
5.0 seconds
120 Vac
150 Vac
5.0 seconds
80 Vac
120 Vac
5.0 seconds
120 Vac
150 Vac
5.0 seconds
60 Vac
120 vac
5.0 seconds
60.2 Hz
65.0 Hz
50.2 Hz
55.0 Hz
5.0 seconds
55.0 Hz
59.8 Hz
45.0 Hz
49.8 Hz
25.0 seconds
302 seconds
Y or N
Y
5 Aac
20 Aac
5 Aac
28 Aac
Vented or Sealed
79