Outback FXR2012A Operator's Manual page 77

Fxr series inverter/charger
Table of Contents

Advertisement

Field
Aux Control
Aux Mode
(Load Shed) ON: Batt >
(Load Shed ON) Delay
(Load Shed) OFF: Batt <
(Load Shed OFF) Delay
(Gen Alert) ON: Batt <
(Gen Alert ON) Delay
(Gen Alert) OFF: Batt >
(Gen Alert OFF) Delay
Auxiliary Output
(Vent Fan) ON: Batt >
(Vent Fan) Off Delay
(DC Divert) ON: Batt >
(DC Divert ON) Delay
(DC Divert) OFF: Batt <
(DC Divert OFF) Delay
(AC Divert) ON: Batt >
(AC Divert ON) Delay
(AC Divert) OFF: Batt <
(AC Divert OFF) Delay
Inverter Stacking
Stack Mode
Power Save
Mode = Master:
Ranking
Mode = Slave:
Offset Enable
Grid-Tie Sell
Sell Voltage
AC Input Voltage
Calibrate
AC Output Voltage
Battery Voltage
Grid Interface Protection Menu
Operating Frequency
Operating Frequency
15
Stage 1 Voltage Trip
Over Voltage Clearance Time
Over Voltage Trip
Under Voltage Clearance Time
Under Voltage Trip
Stage 2 Voltage Trip
15
Over Voltage Clearance Time
Over Voltage Trip
Under Voltage Clearance Time
Under Voltage Trip
Frequency Trip
15
Over Frequency Clearance Time
Over
Frequency Trip
Under Frequency Clearance Time
Under
Frequency Trip
Clearance Time
15
Mains Loss
Reconnect Delay
Multi-Phase Coordination
Sell Current Limit
Maximum Sell Current
Model Select
15
The grid-interactive function is not available in 12-volt models. Adjusting these items will not affect operation.
900-0167-01-00 Rev A
Table 23
FXR Settings for 12-Volt Models
Item
Master Power Save Level
Slave Power Save Level
60-Hz system
50-Hz system
60-Hz system
50-Hz system
Coordin. AC Connect/Disconn.
Default
Minimum
Auto
Load Shed, Gen Alert, Fault, Vent Fan, Cool Fan,
Vent Fan
DC Divert, GT Limits, Source Status, AC Divert
14.0 Vdc
0.5 minutes
0.1 minutes
11.0 Vdc
0.5 minutes
0.1 minutes
11.0 Vdc
0.5 minutes
0.1 minutes
14.0 Vdc
0.5 minutes
0.1 minutes
14.0 Vdc
0.5 minutes
0.1 minutes
14.0 Vdc
0.5 minutes
0.1 minutes
11.0 Vdc
0.5 minutes
0.1 minutes
14.0 Vdc
0.5 minutes
0.1 minutes
11.0 Vdc
0.5 minutes
0.1 minutes
Master, Slave, L2 Phase Master, B Phase Master,
Master
0
1
Y
13.0 Vdc
X
0 Vac
X
0 Vac
X
0.0 Vdc
60 Hz
X
X
1.0 seconds
0.12 seconds
132 Vac
X
2.0 seconds
0.12 seconds
X
X
106 Vac
X
0.16 seconds
0.12 seconds
144 vac
X
X
0.16 seconds
0.12 seconds
X
60 Vac
X
0.16 seconds
0.12 seconds
60.5 Hz
X
50.5 Hz
0.16 seconds
0.12 seconds
X
59.3 Hz
X
49.3 Hz
X
2.0 seconds
1.0 seconds
X
300 seconds
2 seconds
N
X
This selection inoperative in 12-volt models
Vented
X
Specifications
Maximum
Off, Auto or On
10.0 Vdc
18.0 Vdc
25.0 minutes
10.0 Vdc
18.0 Vdc
25.0 minutes
10.0 Vdc
18.0 Vdc
25.0 minutes
10.0 Vdc
18.0 Vdc
25.0 minutes
10.0 Vdc
18.0 Vdc
25.0 minutes
10.0 Vdc
18.0 Vdc
25.0 minutes
10.0 Vdc
18.0 Vdc
25.0 minutes
10.0 Vdc
18.0 Vdc
25.0 minutes
10.0 Vdc
18.0 Vdc
25.0 minutes
C Phase Master
0
10
1
10
Y or N
11.0 Vdc
16.0 Vdc
–7 Vac
7 Vac
–7 Vac
7 Vac
–0.2 Vdc
0.2 Vdc
50 Hz, 60 Hz
5.0 seconds
120 Vac
150 Vac
5.0 seconds
80 Vac
120 Vac
5.0 seconds
120 Vac
150 Vac
5.0 seconds
60 Vac
120 vac
5.0 seconds
60.2 Hz
65.0 Hz
50.2 Hz
55.0 Hz
5.0 seconds
55.0 Hz
59.8 Hz
45.0 Hz
49.8 Hz
25.0 seconds
302 seconds
Y or N
Vented or Sealed
77