Table 23 Fxr Settings For 12-Volt Models - Outback FXR2012A Operator's Manual

Fxr series inverter/charger
Table of Contents

Advertisement

Specifications
items is changed in a mode menu, all menus with this set point will show the same change.
Certain menus are only visible when the installer password is used, particularly the Grid Interface
Protection menu. These menus are bordered in the table with a double line of this style:
Field
INVERTER Hot Key
Inverter Mode
CHARGER Hot Key
Charger Control
AC Input Hot Key
AC Input Mode
Sensitivity (see page 28 for increments)
Search
Pulse Length
Pulse Spacing
Input Type
Charger Control
AC Input and
Grid Input AC Limit
Current Limit
Gen Input AC Limit
Charger AC Limit
Input Mode
Voltage Limit Lower
(Voltage Limit) Upper
Transfer Delay
Grid AC Input
Connect Delay
Mode and Limits
If Mini Grid mode
is selected:
If GridZero mode
is selected:
Input Mode
Voltage Limit Lower
(Voltage Limit) Upper
Transfer Delay
Gen AC Input
Connect Delay
Mode and Limits
If Mini Grid mode
is selected:
If GridZero mode
is selected:
AC Output
Output Voltage
Cut-Out Voltage
Low Battery
Cut-In Voltage
Absorb Voltage
(Absorb) Time
Float Voltage
Battery Charger
(Float) Time
Re-Float Voltage
Re-Bulk Voltage
Equalize Voltage
Battery Equalize
(Equalize) Time
76
Table 23
FXR Settings for 12-Volt Models
Item
FXR2012A
VFXR2812A
Connect to Grid
(Connect) Delay
DoD Volts
FXR2012A
DoD
Amps
VFXR2812A
Connect to Grid
(Connect) Delay
DoD Volts
FXR2012A
DoD
Amps
VFXR2812A
Default
Minimum
Off
On
Use
30
8 AC Cycles
4 AC Cycles
60 AC Cycles
4 AC Cycles
Grid
On
60 Aac
60 Aac
12 Aac
16 Aac
Support
Generator, Support, UPS, Backup, Mini Grid, Grid Zero
108 Vac
132 Vac
1.0 second
0.12 seconds
0.2 minutes
0.2 minutes
12.0 Vdc
10 minutes
2 minutes
12.5 Vdc
12 Aac
12 Aac
Generator
Generator, Support, UPS, Backup, Mini Grid, Grid Zero
108 Vac
140 Vac
1.0 second
0.12 seconds
0.5 minutes
0.2 minutes
12.0 Vdc
10 minutes
2 minutes
12.5 Vdc
12 Aac
12 Aac
X
120 Vac
10.5 Vdc
12.5 Vdc
14.4 Vdc
1.0 hours
0.0 hours
13.6 Vdc
1.0 hours
0.0 hours
12.5 Vdc
12.0 Vdc
14.6 Vdc
1.0 hours
0.0 hours
Maximum
On, Off, or Search
On or Off
Drop or Use
0
200
20 AC Cycles
120 AC Cycles
Grid or Gen
On or Off
5 Aac
60 Aac
5 Aac
60 Aac
0 Aac
14 Aac
0 Aac
18 Aac
85 Vac
110 Vac
125 Vac
140 Vac
4.0 seconds
25.0 minutes
11.0 Vdc
16.0 Vdc
200 minutes
11.0 Vdc
16.0 Vdc
1 Aac
16 Aac
1 Aac
22 Aac
85 Vac
110 Vac
125 Vac
140 Vac
4.0 seconds
25.0 minutes
11.0 Vdc
16.0 Vdc
200 minutes
11.0 Vdc
16.0 Vdc
1 Aac
16 Aac
1 Aac
22 Aac
100 Vac
130 Vac
9.0 Vdc
12.0 Vdc
10.0 Vdc
14.0 Vdc
11.0 Vdc
16.0 Vdc
24.0 hours
11.0 Vdc
16.0 Vdc
24/7
11.0 Vdc
16.0 Vdc
11.0 Vdc
16.0 Vdc
11.0 Vdc
17.0 Vdc
24.0 hours
900-0167-01-00 Rev A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vfxr2812aVfxr3524aFxr2524aVfxr3648aFxr3048a

Table of Contents