Insert Placement Requirements; Masonry Fireplace Requirements; Drafting Performance; Flue Installation - Lopi Freedom Bay ND Owner's Manual

Wood-burning masonry fireplace insert
Hide thumbs Also See for Lopi Freedom Bay ND:
Table of Contents

Advertisement

Insert Placement Requirements

The insert must be placed so that no combustibles are within, or can swing within (e.g. drapes,
doors), 36" (915mm) of the front of the insert
Insert and hearth must be installed on a level, secure floor
The minimum clearances, facing, and hearth requirements in Figure 3 must be met.
Minimum Clearances
a Mantel
(combustible)
with Mantel Shield
b Top Facing
(non-combustible)
with Mantel Shield
c Side Facing
(non-combustible)
d Sidewall

Masonry Fireplace Requirements

Chimney must have a clay tile liner or a stainless steel liner (positive connection)
Entire fireplace, including chimney, must be clean and undamaged. Any damage must be repaired
prior to installation of the insert
Chimney height: 15' (4.5M) minimum; 33' (10M) maximum (measured from the base of the insert).
Entire fireplace, including chimney, must meet local building requirements

Drafting Performance

This appliance relies upon natural draft to operate. External forces, such as wind, barometric pressure,
topography, or factors of the home (negative pressure from exhaust fans, chimneys, air infiltration, etc.),
may adversely affect draft. Travis Industries cannot be responsible for external forces leading to less
than optimal performance.

Flue Installation

Included in the owner's pack are
three "flue brackets" and six self-
drilling screws. Use these
components to secure the flue to the
fireplace insert.
Flue Opening
© Travis Industries
Installation
(for qualified installers only)
Masonry Fireplace
32" 813mm
- - - - - - - - - - - - - - -
19" 483mm
30" 762mm
- - - - - - - - - - - - - - -
17" 432mm
13.5" 343mm
15" 381mm
Flue (flexible or rigid)
Flue Bracket
Self-Drilling Screws
100-01279
RLH Chim-Flex Starter Sections
RLH manufactures starter
sections in straight or
angled configurations to
suit your application.
They are secured from
inside the firebox, making
installation much easier.
Contact RLH for additional
details:
www.chim-flex.com
9
Figure 3
4141215

Advertisement

Table of Contents