Insert Placement Requirements; Masonry Fireplace Requirements; Drafting Performance - Lopi 1750i Inbuilt Owner's Manual

Wood-burning masonry fireplace insert
Table of Contents

Advertisement

Insert Placement Requirements

The insert must be placed so that no combustibles are within, or can swing within (e.g. drapes,
doors), 915mm of the front of the insert.
Insert and hearth must be installed on a level, secure floor.
The minimum clearances, facing, and hearth requirements in Figure 3 must be met.
Minimum Clearances
a Mantel
(combustible)
with Flue Shield
b Top Facing
(non-combustible)
with Flue Shield
c Side Facing
(non-combustible)
d Sidewall

Masonry Fireplace Requirements

Chimney must have a clay tile liner or a stainless steel liner (positive connection)
Entire fireplace, including chimney, must be clean and undamaged. Any damage must be repaired
prior to installation of the insert
Chimney height: 4.5m minimum; 10m maximum (measured from the base of the insert).
Entire fireplace, including chimney, must meet local building requirements

Drafting Performance

This appliance relies upon natural draft to operate. External forces, such as wind, barometric pressure,
topography, or factors of the home (negative pressure from exhaust fans, chimneys, air infiltration, etc.),
may adversely affect draft. Travis Industries cannot be responsible for external forces leading to less
than optimal performance.
© Travis Industries
Installation
(for qualified installers only)
Masonry Fireplace
775mm
572mm
724mm
521mm
330mm
381mm
100-01280
9
Figure 3
4141215