14
Fireplace Insert Installation
Surround Panel Installation
Standard Size
1. Before installing, the insert should be in place with the flue attached. Attach the brackets as
shown below, using the screws included in the hardware pack with the insert. Make sure the
brackets are flush with the front of the convection chamber.
2. Attach the surround panel as shown below.
NOTE: When installing the panel, route the power cord and rheostat wires through the notch on the bottom of
the panel (right side). Route the catalytic temperature probe wire through the notch on the left side.
Make sure these wires do not become pinched or damaged during panel and face installation.
Face Installation
There are several face options available for this fireplace insert. Refer to the instructions included with
your face.
© Travis Industries
(for qualified installers only)
Width
42"
100-01273
Height
32-1/2"
Part#
96100392
4150514