2.3 Image scanning process

2.3.1 Structure and process of RADF
2.3.1.1 Cross-section view
[1] [2] [3]
[12]
[15]
[14]
[13]
[11]
[10]
[1] Lower regist roller
[2] Upper regist roller
[3] Separator roller
[4] Separator pad
[5] Feed paper roller
[6] Document feed tray
[7] Unloading paper inversion upper roller
[8] Unloading paper inversion lower roller
[9] Read roller, 2 pieces
[10] Read roller 2
[11] Platen roller
[12] Read bearer
[13] Read roller 1
[14] Read roller, 1 piece
[15] White sheet
43967002TH Rev.1
[4] [5]
[6]
[9]
[8]
[7]
2.3.1.2 Electrical configuration
Electrical circuit configuration
Electrical control of the MFP is executed by the reader controller circuit PCB and the image
processor circuit PCB. The ASIC of the reader controller circuit PCB and the ASIC of the
image processor circuit PCB interpret the input signals that are supplied from sensors and
the signals that are supplied from the externally connected equipment. The ASICs output the
signals that drive the DC load devices such as motor and solenoid in accordance with the
specified timings. The ADF driver circuit PCB and the reader controller circuit PCB do not
contain the memory area. The data such as service mode data is stored in the processor
circuit PCB.
ADF driver PCB
CN1
CN2
CN10
+3.3V
P151
P150
Scanner RADF PCB
2. Theory of Operation
Motor
Sensor
Solenoid
+24V
Main PCB