Oki Data CONFIDENTIAL
4.2.3.21 Paper feed roller (tray 1)
Note! The paper feed roller and the separator piece should be replaced together as
a pair.
(1) Turn OFF the power of the MFP , and remove the paper cassette.
(2) While opening the feed paper roller (large)
43967002TH Rev. 1
Paper cassette
outside, remove it from the axis.
Claw
(3) Remove the spring
from the paper cassette.
(4) Bend the separator piece
until one foot of the separator piece is removed from
the pivot, and remove it in the manner of raising it up.
Flat head screwdriver
Separator piece:
[Caution when installing the feed paper roller]
1.
When installing the new feed paper roller, insert it into the axis, and insert it
securely by rotating it until it reaches the deep end. At the same time, confirm that
the roller does not come off.
4. Part Replacement
Flat head screwdriver
Spring
Pivot
Flat head screwdriver
Foot
Separator piece:
186 /