BLSL3060 Manual_Layout 1 2/10/2014 5:00 PM Page 19
Installation: ElecTrical
power cable to the board. USE MIN. 14 AWG WIRE. FOLLOW ALL LOCAL ELECTRICAL CODES.
To help protect the equipment from lightning and power
surges and to protect persons from shock hazard the
Operator must be grounded. The earth ground rod
must be located within 3 feet from the gate operator.
Use the proper type earth ground rod for your local
area. The ground wire must be a single, whole piece of
wire. Never splice two wires for the ground wire. If you
cut the ground wire too short, break it, or destroy
its integrity, replace it with a single wire length.
Prevent unnecessary turns or loops in ground wires.
The gate operator and the battery charger require a
single phase AC line to operate.
1. Turn off the breaker for the circuit you are using.
2. Select the proper voltage on the power board.
3. Connect the incoming power wires to the proper
terminals.
4. Turn on the breaker and check that AC ON and
CHARGE LED are lit.
115V/230V
Power Switch
Blue
To
Transformer
Red
The power receptacle has been left unconnected till the installer decides what voltage to use.
Connect to 120VAC only
BLSL3060
Hot
Neutral
Power Ground
Earth Ground
TECHNICAL SUPPORT: (909) 259-6001
Black
Green
Red
White
To AC Power
Power Harness
Earth Ground
Ground Rod