BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 3 Installation Instructions & Safety Information Manual BLSW2212 Installation Instructions and Safety Information Manual: Vehicular Gate Operator Class I, Class II, Class III, and Class IV Safety Information ..........4-8 Installation ..........9-10 Inductive Loops ...........11-12...
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 4 SAFETY INFORMATION WARNING – To reduce the risk of severe injury or death to person, please to follow these instructions: 1. READ AND FOLLOW ALL INSTRUCTIONS MANUAL BEFORE ATTEMPTING ANY INSTALLA- TION.
Page 5
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 5 SAFETY INFORMATION WARNING – To reduce the risk of severe injury or death to person, please to follow these instructions: GENERAL SAFETY PRECAUTIONS WITH THE END-USER: 1. Instruct the end-user on how to safely operate all functions of the operator.
Page 6
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 6 SAFETY INFORMATION WARNING – To reduce the risk of severe injury or death to person, please to follow these instructions: IMPORTANT INSTALLATION INSTRUCTIONS BY UL STANDARDS: (CONTINUED FROM PREVIOUS PAGE) 4. The gate must be properly installed and work freely in both directions prior to the installation of the gate operator.
Page 7
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 7 gate operator class categories and examples WARNING – To reduce the risk of severe injury or death to person, please to follow these instructions: CAUTION: To Reduce the Risk of Fire or Injury to Persons Use only the type and size of batteries provided on an AC powered system: OUTDO-OT7-12 disposal instructions.
Page 8
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 8 SAFETY INFORMATION WARNING – To reduce the risk of severe injury or death to person, please to follow these instructions: 12'-0" FOR USE WITH GATES OF A MAXIMUM OF 12 FT IN LENGTH 2200 lb.
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 9 INSTALLATION WARNING – To reduce the risk of severe injury or death to person, please to follow these instructions: Note: This type of installation DOES NOT reverse the gate all the way back to its limits when the photo- beam is obstructed.
Page 10
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 10 INSTALLATION WARNING – To reduce the risk of severe injury or death to person, please to follow these instructions: Note: This type of installation DOES NOT reverse the gate all the way back to its limits when the photo- beam is obstructed.
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 11 Installation: Inductive Loops WARNING – Consult the installation instructions from the loop detector manufacturer. The following statements are provided as a guide but different requirements may be required by the vehicular loop detector manufacturer.
Page 12
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 12 Installation: Inductive Loops WARNING – This product is an accessory or part of a system. Always read and follow the manufactur- er’s instructions for the equipment before connecting this product. Comply with all applicable codes and safety regulations.
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 13 Installation: Alarm Reset Switch & Warning Placards WARNING – To reduce the risk of severe injury or death to person, please to follow these instructions: Alarm Reset Switch Installation: (UL 325 standard requires) An audible alarm to go off after two consecutive events detected by the primary entrapment protection of the gate operator.
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 14 PLAN OF INSTALLATION Plan of Installation: The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment.
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 15 PLAN OF INSTALLATION Plan of Installation (continued): Concrete Pad 10" 3-1/4" 2-7/16" Operator Cover 23-1/4" 7-5/8" Operator Center of Output Shaft Chassis Gate Operator Concrete Pad Drill for a 1/2" x 3-1/2"...
Page 16
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 16 PLAN OF INSTALLATION Plan of Installation (continued): CAUTION Do not weld the bar or backing plate to only a few gate posts. Mounting bar must be welded to a frame segment that runs the full length of the gate to prevent damage to the gate operator.
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 17 PLAN OF INSTALLATION Plan of Installation (continued): STEP 4 Once satisfied with the arrangement of the articulated arm and bracket, weld all pieces securely. Paint the arm to preserve it from rusting.
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 18 Installation: ElecTrical Electrical Installation: To help protect the equipment from lightning and power surges and to protect persons from shock hazard the Operator must be grounded. The earth ground rod must Black be located within 3 feet from the gate operator.
Page 19
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 19 Installation: ElecTrical Connecting Power: Connect the LIMIT harness to J14, and MOTOR CTL harness to J4. On the OPEN DIR switch: Select “RIGHT” to open right. Select “LEFT” to open left. OPEN LEFT...
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 20 Installation: LIMIT SWITCH SET-UP Limit Switch Set-Up: STEP 7 Cam Wheel A. Loosen the screws on the Limit Switch Cams. B. Remount the articulated arm, making sure the cam wheel pin is engaged with the clutch.
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 21 Installation: LIMIT SWITCH SET-UP Limit Switch Set-Up (continued): OPENING/CLOSING SETUP Slow 1. Setup the limit switches manually at the desired open and close position. 2. Allow the gate operator to run a full open...
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 22 Installation: Primary/Secondary Connections Electrical Installation - Primary/Secondary: Outside Secondary Primary Interconnecting Conduit Inside Caution – Do not run Primary/Secondary communication cable (Model #PA-PSC100) in the same conduit as the power supply (120-220V) cable.
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 24 Installation: Accessory Connections Accessory Connections: To decrease the possibility of vehicle entrapment on the gate, vehicle loop detectors need to be installed. The edge sensor and the photo- electric beam can be used for secondary entrapment protection on every installation to prevent pedestrian or animal entrapment.
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 25 Installation: Accessory Connections ACCESSORY CONNECTIONS (continued): Radio Receiver Need to verify the proper connections before connecting the Radio Receiver. The maximum voltage that the control board / battery can provide is about 28V for external accessories.
Page 26
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 26 Installation: Accessory Connections Accessory Connections (continued): Solenoid Connection The solenoid power connection must be provided an external power source. This will prevent damage to the battery in the event of a line power failure.
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 27 Installation: Accessory Connections ACCESSORY CONNECTIONS (continued): Locks Magnetic Lock (#PA-MAG13) (Supplied with Lock Kit) (Supplied with Lock Kit) Green Black 24VDC White The Magnetic Lock power connection must be provided an external power source. This will prevent damaging the battery in the event of line power failure.
Select the DIP switch to ADV MLOK position. OPEN ON POWER FAIL: The Auto-Open feature in Platinum Access Systems Gate Operators enables the following functionality in the event of power failure: a. Open the gate in case of power failure (120 or 220 VAC).
Page 29
BLSW2212 Manual_Layout 1 2/10/2014 5:11 PM Page 29 Installation: Selectable Features CLOSE TIMER: Close Timer The Close Timer will close the gate a set time after the vehicle clears the gate area. This is adjustable from 3 to 60 seconds.
Need help?
Do you have a question about the BLSW2212 and is the answer not in the manual?
Questions and answers