Entrapment Protection - Platinum Access Systems BLSL3060 Installation Instructions & Owner's Manual

Vehicular gate operator
Table of Contents

Advertisement

BLSL3060 Manual_Layout 1 2/10/2014 5:00 PM Page 15
Installation: entrapment protection
Note: This type of installation DOES NOT reverse the gate all the way back to its limits when the sensors
are obstructed. This installation is only to protect against entrapment and to comply with UL325.
Contact Sensor Installation:
Only sensors compliant with UL 325 are recommended.
Non-Contact Sensors (Photoelectric Sensors) Installation:
One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists,
such as the perimeter reachable by a moving gate or barrier.
Install photoelectric sensors to protect
against any entrapment or safety conditions
encountered in your gate application.
We recommend the use of EMX IRB-325
photoeyes to comply with UL325.
Reflector
Potential Entrapment Area
Consult the UL325 device installation manual for more detail information about the usage,
installation and maintenance of this device.
BLSL3060
All Contact Sensors to
be wired in parallel
Contact
Sensor
Photo Beam
Unit
Contact Sensor
TECHNICAL SUPPORT: (909) 259-6001
Connection '1' (C1)
Connection '2' (NC1)
Gate in Closed Position
Contact
Sensor
TX
EMX Model
IRB-325
Shown
Contact
Sensor
13