Mounting Instructions

CONCRETE PAD
Install a
Positive Stop
at Both Ends
of the Track
10
Track
20"
Operator Cover
Operator Chassis
4"
20
3
/
8
28"
Chain
12
/
"
7
8
24"
Gate Operator Concrete Pad
1. Follow the local building code to determine the requirement of the concrete pad.
2. We recommend the Pad measurements should be at least 28 " long, 20 " wide,
and 24 " deep to ensure the stable operation of the operator, and a minimum
of 4 " above level grade to avoid any flooding of the operator.
3. To support the weight of the gate, we recommend the path of the track should be
at least 10 " wide and 6 " deep.
TECHNICAL SUPPORT: (909) 259-6001
Gate
2"
9
1
/
"
4
Track Concrete Pad
Minimum
6"
Gate Operator Concrete Pad
"
Drill for a
/
" x 3
/
"
1
1
2
2
Red Head Anchor
(4) Places
4"
Minimum
Grade Level
See Note 2
Track Concrete Pad
10"
6"