Pacific energy NEO 2.5 NEWCASTLE Installation And Operating Instructions Manual

Pacific energy NEO 2.5 NEWCASTLE Installation And Operating Instructions Manual

A series

Advertisement

IMPORTANT:
THESE INSTRUCTIONS ARE TO
REMAIN WITH THE HOMEOWNER

SAFETY NOTICE

If this stove is not properly installed, a house
fire may result. For your safety, follow the
installation instructions.
building or fire officials about restrictions
and installation inspection requirements in
your area.
TESTED and LISTED to CAN/ULC S627
AND UL 1482
Meets the Environmental Protection
Agency's May 2015 Particulate Emission
Standards
©PACIFIC ENERGY FIREPLACE
150715-24
PRODUCTS LTD. - 2014
Contact local
NEO25 - NEWCASTLE
INSTALLATION
AND OPERATING
INSTRUCTIONS
MODEL - NEO 2.5 NEWCASTLE
SERIES - A
SERIAL #
5055.880

Advertisement

Table of Contents
loading

Summary of Contents for Pacific energy NEO 2.5 NEWCASTLE

  • Page 1: Safety Notice

    TESTED and LISTED to CAN/ULC S627 AND UL 1482 Meets the Environmental Protection Agency's May 2015 Particulate Emission Standards MODEL - NEO 2.5 NEWCASTLE SERIES - A ©PACIFIC ENERGY FIREPLACE 150715-24 NEO25 - NEWCASTLE 5055.880 PRODUCTS LTD. - 2014...
  • Page 2: Table Of Contents

    Label ..........................23 PLEASE SAVE THESE INSTRUCTIONS This manual describes the installation and operation of the Pacific Energy, NEWCASTLE 2.5 Freestanding wood woodstove. This woodstove meets the 2015 U.S. Environmental Protection Agency's crib wood emission limits for wood woodstoves sold after May 15, 2015. Under specific test conditions this woodstove has been shown to deliver heat at rates ranging from 11,500 to 32,600 Btu/hr.
  • Page 3: Safety

    Chimney fires are easy to detect; they usually involve one or more of the following: -Flames and sparks shooting out of the top of the chimney -A roaring sound -Vibration of the chimney 150715-24 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 4: Operation

    Contact may cause skin burns. igniting in five minutes it is soaked and should not be burnt. Your PACIFIC ENERGY woodstove is designed for many years Lighting a Fire of trouble free operation. Over firing the appliance will shorten the life of the product.
  • Page 5: Restarting After Extended Or Overnight Burns

    WARNING: IF YOU CHOOSE TO STORE WOOD BENEATH woodstove and will obtain the performance for which it was YOUR UNIT, EXERCISE EXTREME CAUTION WHEN designed. LOADING THE WOODSTOVE. EMBERS CAN FALL AND MAY IGNITE WOOD BENEATH STOVE. 150715-24 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 6: Maintenance

    Failure to prevent ash or soot from falling into the baffle tube will cause incorrect operation and will lead to premature burn out of the tube or baffle. 150715-24 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 7: Maintenance Checks

    - Please contact your dealer if you experience any of the damage listed above. Continuing to operate your stove with bro- ken parts may accelerate damage to other parts and may void your warranty 150715-24 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 8: Cast Iron Parts

    2) The Top Wings can be removed by lifting and rotating back and forth. This will slowly slide the pin from the bushing in the mounting bracket. Fig #2 150715-24 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 9 5) While support the side panel, remove the two bolts securing FIG. #4 BOLTS the top of the side panel to the unit. Fig. #4 6) Lift the side panel to disengage the bottom brackets from the slots in the leg bottom. 150715-24 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 10 Remove the screws securing the leg adapter cover to the mounting brackets on the left and right of the leg adapter cover. Fig. #7 11) Reverse all previous steps in order when installing new or replacement pieces. SCREW AND MOUNTING BRACKET 150715-24 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 11: Ember Protection

    If blockage occurs, flue gases may enter living space. 16" [406mm] (Type 1 floor protector - approved to UL1618) Minimum 20GA steel 150715-24 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 12: Residential Installation

    (3 m.). The installation must meet all local codes. Do not connect this unit to a chimney flue serving another appliance. Minimum system height is 15 feet (4.6 m.) (measured from base of appliance). 150715-24 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 13 11" 5" 11" 5" 279mm 127mm 279mm 127mm 3" 15 5/8" 8" 76mm 397mm 8" 8" 203mm 203mm 203mm 22 1/2" 572mm 22 1/2" 3" 572mm 76mm Alcove: Min. Height 7' Max. Depth 3' 150715-24 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 14 Hooded vent or 90 elbow turned down * 4"(102mm) diameter air inlet with rodent screen * If the crawl space is well ventilated it is not necessary to extend air inlet to outside 150715-24 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 15 * 4"(102mm) diameter air inlet with Hooded vent or rodent screen 90 elbow turned down * If the crawl space is well ventilated it is not necessary to extend air inlet to outside 150715-24 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 16: Mobile Home Installation

    (Seal securely.) Attach rain cap and check flashing for leaks. 8. Install connector and chimney as per manufacturer's instructions. 9. Attach stove to flooring using two 1/4"(6mm) x 2"(51mm) or longer lag screws. 150715-24 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 17: Optional Blower

    "Man" and set the speed control to desired setting. This will bypass the sensing device and allow full control of the blower. Switching from "Auto" to "Man" or selecting speed may be done anytime. FIG. #14 PIPE SHIELD (CA25.78727) OUTSIDE AIR ADAPTER (OAIR.1A) 150715-24 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 18: Troubleshooting

    1. Combustion air supply blocked - Check outside air supply for obstruction - Check that room air cover is removed 2. Draft too low - Chimney plugged or restricted, inspect and clean - Chimney oversized or otherwise unsuitable, consult Dealer 150715-24 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 19: Replacement Parts - Newcastle 2.5

    15 ..Ash Drawer..........NE25.78352 PORCELIN BLACK: ............BKA PORCELIN MAJOLICA BROWN ........BNA PORCELIN ANTIQUE WHITE .......... AWA METALIC BLACK PAINT..........MBKA All parts may be ordered from your nearest Pacific Energy dealer. http://www.pacificenergy.net for the location of the dealer nearest you. 150715-24 ©PACIFIC ENERGY FIREPLACE...
  • Page 20: Understanding & Operating Your Pacific Energy Stove

    Understanding & Operating Your Pacific Energy Stove The Pacific Energy SUPER SERIES line of woodstoves is a OPERATING TIPS culmination of years of research and development. Designed to be efficient, clean-burning and user-friendly, this heater will 1. Always use dry, seasoned firewood, up to 18"(457mm) long.
  • Page 21: Firebrick Installation Instructions

    7847.3 4 1/2" X 4 1/2” X 1 1/4” (115 mm x 115 mm x 32 mm) 7847 2 1/8" X 4 1/2” X 1 1/4” (57mm x 115 mm x 32 mm) 7847.1 150715-24 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 22: Warranty Information

    3 Year Comprehensive Pacific Energy will replace or repair any part found to be defective (parts and labor) for three years from the date of pur- chase. This coverage includes electrical components (blowers, speed controls and thermal switches).
  • Page 23: Label

    Label MUR COTE MUR ADJACENT SIDE WALL ADJACENT WALL COTE SIDE 150715-24 ©PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
  • Page 24 PACIFIC ENERGY FIREPLACE PRODUCTS LTD. 2975 Allenby Rd., Duncan, B.C. V9L 6V8 For technical support, please contact your retailer. Web site: http://www.pacificenergy.net Printed in Canada...