MPC564EVB Jumper and Switch Setup

"The Terminal Character Format".) The baud rate should be set to 19200. Power can now be
applied to the board.
Figure 2-2. Pin assignment for female (Terminal) connector.
Pin assignments are as follows.
Pin 1, 4, and 6 = group connected for DTR/DSR flow control null back to host
Pin 2 = TXD output (RS232 level)
Pin 3 = RXD input (RS232 level)
Pin 5 = Ground/Vss/Common
Pin 7 and 8 = group connected for RTS/CTS flow control null back to host
Pin 9 = open
2.3 MPC564EVB Jumper and Switch Setup
Jumper settings are as follows:
Note '*' is used to indicate that default setting.
'**' is used to indicate mandatory setting for proper operation.
Jumper Setting
JP1
JP2
JP3
BRK_EN
B_RX
2-6
PRELIMINARY—SUBJECT TO CHANGE WITHOUT NOTICE
5
9
Table 2-2. Jumper Settings
* 1-2,3-4
COM2: TX=Pin3, RX=Pin2 (see silk screen on bottom of
board)
1-3,2-4
COM2: TX=Pin2, RX=Pin3 (see silk screen on bottom of
board)
Determines the display power pin polarity on the
LCD_PORT. See the schematic
*1-2 (closest to
BDM being used runs at 3.3 volts. So the signals need to go
RS232
through a level shifter to get 2.6 volts to the part.
connectors)
2-3
BDM being used runs at 2.6 volts.
*inserted
SWITCH1 will act as a debounced Non-Maskable Interrupt
(ABORT)
removed
SWITCH1 is for user use
*insterted
CAN: see section 1.3.2
removed
CAN: see section 1.3.2
MPC564EVB User's Manual