4-4 �lo�er Reset
�lo�er Reset
After replace main board/blower or upgrade system FW, you need to do:
(1) Get into Service Mode.
(2) Select "Blower Factory RPM", then click "Enter" button.
Note: The steps must be finished in a minute after powering on projector.

4-5 Test Condition

- Circumstance brightness: Dark room less than 2 lux.
- Inspection distance: 0.5m~1.0m functional inspection.
- Screen size: 60 inches diagonal.
- After repairing each unit, a Run-in test is necessary (refer to the below table).
Symptom
Normal repair
NFF
Auto shutdown
- Get into Burn-In Mode
* Cycle setting is based on the defect symptoms. ie: If it is NFF, the run-in time is 4 hours. You have
to set the lamp on for 50 min. and lamp off for 10 min for 4 cycles.
Press power > Enter > Enter > Menu to get into service mode
Choose Burn-In Test > enter
Lamp On
Lamp Off
Set burn in cycle
After setting up the time, choose "Get into Burn-In Mode" and press enter
Run-in Time
2 hours
4 hours
6 hours
Press right key to adjust the time (50)
Press right key to adjust the time (10)
Press right key to adjust the cycle
PDG-DWL100