Specifications
Range &
Function
Resolution
AC Current
40.00A AC
50/60 Hz
400.0A AC
800A AC
AC Voltage
400.0mV AC
50/60Hz
4.000V AC
40.00V AC
400.0V AC
600V AC
DC Voltage
400.0mV DC
4.000V DC
40.00V DC
400.0V DC
600V DC
Resistance
400.0Ω
4.000kΩ
40.00kΩ
400.0kΩ
4.000MΩ
40.00MΩ
Capacitance
4.000nF
40.00nF
400.0nF
4.000µF
40.00µF
400.0µF
4.000mF
40.00mF
4.000kHz
Frequency
Sensitivity: 100V (<50Hz); 50V (50 to 400Hz); 5V (401 to 4000Hz)
Accuracy (% of reading + digits)
± (2.8% + 10d)
± (2.8% + 8d)
± (3.0% + 8d)
± (1.5% + 10d)
± (1.8% + 8d)
± (2.5% + 8d)
± (0.8% + 2d)
± (1.5% + 2d)
± (2.0% + 2d)
± (1.0% + 4d)
± (1.5% + 2d)
± (2.5% + 3d)
± (3.5% + 5d)
± (5.0% + 30d)
± (5.0% + 20d)
± (3.0% + 5d)
± (4.0% + 10d)
± (10% + 10d)
unspecified
± (1.5% + 2d)
9