Output Sequence Editor

Enter Sequence

Require Output Sequence

When an output sequence is Required, all output data must conform to an
edited sequence or the image scanner will not transmit the output data to the
host device. When it's On/Not Required, the image scanner will attempt to get
the output data to conform to an edited sequence, but if it cannot, the image
scanner transmits all output data to the host device as is.
When the output sequence is Off, the barcode data is output to the host as the
image scanner decodes it.
Note: This selection is unavailable when the Multiple Symbols Selection is
turned on.
Required
*Off

Multiple Symbols

When this programming selection is turned On, it allows you to read multiple
symbols with a single pull of the scanner's trigger. If you press and hold the trig-
ger, aiming the scanner at a series of symbols, it reads unique symbols once,
Default Sequence
On/Not Required
3 - 13