Output Sequence Overview; To Add An Output Sequence; Other Programming Selections - Honeywell Hyperion 1300G User Manual

General purpose handheld linear scanner
Hide thumbs Also See for Hyperion 1300G:
Table of Contents

Advertisement

Output Sequence Overview

Output Sequence Editor
This programming selection allows you to program the scanner to output data
(when scanning more than one symbol) in whatever order your application
requires, regardless of the order in which the bar codes are scanned. Reading
the Default Sequence symbol programs the scanner to the Universal values,
shown below. These are the defaults. Be certain you want to delete or clear all
formats before you read the Default Sequence symbol.
Note: To make Output Sequence Editor selections, you'll need to know the
code I.D., code length, and character match(es) your application
requires. Use the Alphanumeric symbols (inside back cover) to read
these options.
Note: You must hold the trigger while reading each bar code in a sequence.

To Add an Output Sequence

1. Scan the Enter Sequence symbol (see
13).
2. Code I.D.
On the
Symbology Charts
want to apply the output sequence format. Locate the Hex value for that
symbology and scan the 2 digit hex value from the Programming Chart
(inside back cover).
3. Length
Specify what length (up to 9999 characters) of data output will be acceptable
for this symbology. Scan the four digit data length from the Programming
Chart. (Note: 50 characters is entered as 0050. 9999 is a universal num-
ber, indicating all lengths.) When calculating the length, you must count any
programmed prefixes, suffixes, or formatted characters as part of the length
(unless using 9999).
4. Character Match Sequences
On the
ASCII Conversion Chart (Code Page
value that represents the character(s) you want to match. Use the Program-
ming Chart to read the alphanumeric combination that represents the ASCII
characters. (99 is the Universal number, indicating all characters.)
5. End Output Sequence Editor
Scan F F to enter an Output Sequence for an additional symbology, or Save
to save your entries.

Other Programming Selections

•Discard
This exits without saving any Output Sequence changes.
3 - 10
Require Output
on page A-1, find the symbology to which you
Sequence, page 3-
1252), page A-3, find the Hex