2-D Laser Scanner

Installation

4
Installation
4.1

Mounting

Caution!
Safety information
Do not point the sensor into the sun.
Protect the sensor against direct and prolonged sunlight.
Prevent condensation from forming by ensuring that the sensor is not subjected to
any major temperature fluctuations.
Do not subject the sensor to aggressive chemicals.
Keep the glass on the device clean.
For cleaning, use only water (if necessary with a little detergent) and a soft
microfiber cloth! The use of other detergents is not permitted! The glass must
never be cleaned when dry!
The device can be fitted with the supplied socket head screws with washers on
the underside of the device.
Caution!
Screw-in depth
The maximum screw-in depth in the base must not exceed 8 mm, otherwise the
device will be mechanically destroyed! The minimum screw-in depth is 5 mm.
Figure 4.1
8
70
3 x M5
CLASS 1
LASER PRODUCT
IEC 60825-1: 2007 certified.
Complies with 21 CFR
1040.10 and 1040.11 except
for deviations pursuant to
Laser Notice No. 50,
dated June 24, 2007
20
20
106
Dimensional drawing R2000