3-7-1. Operation failure of pan

Trouble 1
Trouble 2
During pan operation (up and down
movement), the unit hits the mechanical
end point of each upper side and down
side forcefully. After this, the pan does
not operate normally.
Check the signal around the connector,
then replace the SE-656 board,
MDR-19 board or SEN1.
SNC-RZ30N/RZ30P (E)
Operation failure of pan
Is the flexible flat cable (MP1)
correctly connected?
Yes
Check the signal around
the connector, then
replace MP1 or the
MDR-19 board.
Is the harness (SEN1)
correctly connected?
Yes
No
Connect the flexible flat cable
(MP1) correctly.
No
Connect the harness
(SEN1) correctly.