Reconfirmation For Pan/Tilt Operations; Confirmation For Digital Image; Confirmation For Tv Monitor Images; Confirmation For Sensor In And Alarm Out - Sony SNC-RZ30N Service Manual

Hide thumbs Also See for SNC-RZ30N:
Table of Contents

Advertisement

2-6-1. Reconfirmation for Pan/Tilt
Operations
Confirm the pan/tilt operation should operate normally in
smoothly.
1. Click Setting of the Main Viewer screen, type the
"admin" to the user name and password box in the
confirmation screen. Then click OK button.
2. Click Camera menu and select "Optical only" from the
list box of Zoom mode, and then click Apply button.
3. Close the setting screen.
4. Click Control icon.
5. Pressing ← arrow continuously until move to end of
the screen.
6. Confirm the following specification is satisfied.
Specification: Pan operation should operate normally
in smoothly and no abnormal sound
toward Pan direction.
7. Pressing → arrow continuously until move to end of
the screen, confirm the following specification is
satisfied.
Specification: Pan operation should operate normally
in smoothly and no abnormal sound
toward Pan direction.
8. Click O, confirm the following specification is
satisfied.
Specification: Pan position should move normally in
smoothly and no abnormal sound at
home position.
9. Pressing ↑ arrow continuously until move to end of the
screen, confirm the following specification is satisfied.
Specification: Tilt operation should operate normally
in smoothly and no abnormal sound
toward Tilt direction. (Lower direction)
10. Pressing ↓ arrow continuously until move to end of the
screen, confirm the following specification is satisfied.
Specification: Tilt operation should operate normally
in smoothly and no abnormal sound
toward Tilt direction. (Upper direction)
11. Press Tele button continuously until zoom is
maximum position, confirm the following
specification is satisfied.
Specification: No jitter images should display on the
TV monitor.
SNC-RZ30N/RZ30P (E)

2-6-2. Confirmation for Digital Image

Confirm the processor block and ethernet are operated
correctly.
1. Click Control icon.
2. Shot the subject using Pan, Tilt (arrows) and Zoom
(TELE, WIDE) on the Control screen.
3. Close the setting screen.
4. Confirm the following specification is satisfied.
Specification: Normal images (images of turn over at
the upper and lower sides), that may not
occur noisy such as U-matic beat etc,
should be displayed on the PC monitor.
(640 x 480 images)
Subject: Color bar chart plus clock

2-6-3. Confirmation for TV Monitor Images

Specification: Normal images (images of turn over at the
upper and lower sides), that may not occur
noisy such as U-matic beat etc, should be
displayed on the TV monitor. (640 x 480
images)
Subject: Color bar chart plus clock
2-6-4. Confirmation for Sensor In and Alarm
Out
Confirm the sensor in (x3) and alarm out (x2) operates
normally in the terminal table.
1. Click Setting of the Main Viewer screen, type the
"admin" to the user name and password box in the
confirmation screen. Then click OK button.
2. Click Alarm out1 menu, check the radio button in the
"Use alarm out1 function" section. Then, click OK
button.
3. Set as follows and click OK button.
Mode:
Alarm
Alarm:
Sensor1, Sensor2, Sensor3
Available period: Always
Alarm duration: 1
4. Click Alarm out2 menu, check the radio button in the
"Use alarm out2 function" section. Then, click OK
button.
2-27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Snc-rz30p

Table of Contents