R e m o t e T o u c h D i s p l a y
2.11 Connecting Debugging
If the connection or display cannot work well, please refer to the debugging
steps below.
Make sure all of the cabling connected tightly
After the computer/display powers on, you will see the display is
reaching the local and remote IP below
Local IP: The IP address of the display
If the display cannot find the local IP as shown, it means the
network connection/cabling has some issues
Remote IP: The address of the remote box, such as ACG-203
or ACG-204
If the display cannot find the remote IP, it means the remote
box may have some issues, so the IP address in the remote
box cannot be found
Below is the situation, which is searching the IP address
If the display or sound cannot work properly, please try the following
step
Step1: Make sure the local and remote IP can be found. If the IP
address cannot be found, please check the network cabling
Step 2: Make sure the DVI/VGA and audio cable insert tightly