Observe all Safety Guidelines detailed throughout this manual
Error Codes for the Power Wave 455: Code 10555 and below
Note: For any Err # listed below write down the error number for reference and try cycling power to see if the
error clears itself. If not, refer to the What to Do column for the given Err.
PROBLEMS
(SYMPTOMS)
Display shows any of the following:
Err 211
Err 212
- - - (three dashes)
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department at 1-888-935-3877 for electrical troubleshooting assistance before
you proceed.
TROUBLESHOOTING & REPAIR
POSSIBLE CAUSE
Microprocessor RAM error in Control
Box.
Microprocessor RAM Error in object
board other than Control Box (Such
as feed head)
Appears on right display of CB mod-
ule that contains the status LED
CAUTION
POWER FEED 10M SINGLE/DUAL
RECOMMENDED
COURSE OF ACTION
Turn Power off at power source.
Wait 5 seconds. Turn power back
on. If Err 211 is displayed again,
then replace CB mother PC board.
Cycle power as in Err 211. If Err 212
is still displayed, then replace the
PC board in the object with the fault.
The object with the fault should be
solid red on its status LED.
This is an indication that a constant
current such as stick or gauge mode
has been selected. Turning the right
encoder clockwise when in this state
will activate output to Power Source.
Turning the right encoder counter-
clockwise will deactivate output.