Wire Feed Drive Roll Kits; Procedure To Install Drive Rolls And Wire Guides; Gun And Cable Assemblies With Standard Connection; Gun And Cable Assembles With Fast-Mate Connection - Lincoln Electric POWER FEED 10M SINGLE/DUAL SVM172-A Service Manual

Lincoln electric welding system user manual
Table of Contents

Advertisement

AA-8

WIRE FEED DRIVE ROLL KITS

NOTE: The maximum rated solid and cored wire sizes
and selected drive ratios are shown on the
SPECIFICATIONS in the front of this section.
The electrode sizes that can be fed with each roll and
guide tube are stenciled on each part. Check the kit for
proper components. Kit specifications can be found in
the ACCESSORIES section.
PROCEDURE TO INSTALL DRIVE
ROLLS AND WIRE GUIDES
WARNING
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts such
as output terminals or internal wiring.
• When feeding without Power Feed 10 Dual "Cold
Feed" feature, electrode and drive mechanism are
"hot" to work and ground and could remain ener-
gized several seconds after the gun trigger is
released.
• Turn OFF input power at welding power
source before installation or changing drive
roll and/or guide tubes.
• Welding power source must be connected to
system ground per the National Electrical
Code or any applicable local codes.
• Only qualified personnel should
perform this installation.
Drive Roll Kit Installation (KP1505-[ ])
• Turn OFF Welding Power Source.
• Pull open Pressure Door to expose rolls and wire
guides.
• Remove Outer Wire Guide by turning knurled thumb
screws counter-clock-wise to unscrew them from
Feedplate.
Observe all additional Safety Guidelines detailed
throughout this manual.
• Remove drive rolls, if any are installed, by pulling
straight off shaft. Remove inner guide.
INSTALLATION
• Insert inner Wire Guide, groove side out, over the
• Install each drive roll by pushing over shaft until it
• Install Outer Wire Guide by sliding over locating
• Engage upper drive rolls if they are in the "open"
TO SET DRIVE ROLL PRESSURE, see "Drive Roll
Pressure Setting" in OPERATION.
GUN AND CABLE ASSEMBLIES
WITH STANDARD CONNECTION
The Power Feed 10 Dual Wire Feeder is equipped with
a factory installed K1500-2 gun connection Kit. This kit
is for guns having a Tweco™ #2-#4 connector. The
Power Feed 10 Dual Wire Feederl has been designed
to make connecting a variety of guns easy and inex-
pensive with the K1500 series of gun connection kits.
Gun trigger and dual procedure lead connections con-
nect to the single 5 pin receptacle on the front of the
feed head box. See "Gun Adapters" in ACCESSORIES
section.
GUN AND CABLE ASSEMBLIES
WITH FAST-MATE™ CONNECTION
(including the Magnum 450 Water Cooled gun)
A K489-7 adapter will install directly into the wire drive
feedplate, to provide for use of guns with Fast-Mate™
or European style gun connections. This K489-7 will
handle both standard Fast-Mate™and Dual Schedule
Fast-Mate™ guns.
Another way to connect a gun with a Fast-Mate™ or
European style gun connector to the Power Feed 10
Dual Wire Feederl, is to use the K489-2 Fast-Mate™
adapter kit. Installation of this adapter also requires a
K1500-1 gun connector. See "Gun Adapters" in
ACCESSORIES section.
Magnum 200 / 300 / 400 Guns
The easiest and least expensive way to use Magnum
200/300/400 guns with the Power Feed 10 Dual Wire
Feeder is to order them with the K466-10 connector kit,
or to buy a completely assembled Magnum gun having
the K466-10 connector (such as the K497-21 dedicat-
ed Magnum 400).
POWER FEED 10M SINGLE/DUAL
two locating pins in the feedplate.
butts up against locating shoulder on the drive roll
shaft. (Do Not exceed maximum wire size rating of
the wire drive).
pins and tightening in place.
position and close Pressure Door.
AA-8