E 10
Caution: The supply voltage
drops considerably during the
E 11
rotation of the antenna.
E 12
E14
Incorrect feedback from
antenna unit.
E 15
E 16 Incorrect model configuration. Error occurred during model
E 17 Re-Init activated.
E 18 Limit switch/mechanical fault A fault in the antenna unit has been
E 19 Hardware fault
(possibly in conjunction with
OSD message)
Recharge the battery as soon as
possible. Check the wiring and the
connection of the system to the
voltage supply. Observe the
information in the Installation
Instructions!
An incompatible antenna unit is
connected.
The power relay of the antenna unit
The power-supply relay of the
external unit oscillates between
open and closed position or the
contact is soiled or burned (relay
fault).
Potentially strong switch transients
of the power supply (external supply
by charge controllers or
interferences from TV sets).
configuration. An update may have
been performed incorrectly. The
system must be serviced by the
manufacturer.
Undefined memory content
detected. The faults were corrected.
Switch the system off and back on.
You may have to change some
settings
(e. g. search satellite).
detected. Icing may be the cause.
Please contact the service
department.
The automatic self-test revealed a
hardware fault. Do not operate the
system any more, further damage
may occur. The system must be
56