Shutdown Instructions; Storage - Landa SEHW6-3500 Operator's Manual

Table of Contents

Advertisement

STEP 1: Place detergent line in a
bucket of clear water allowing de-
tergent to be flushed from system.
Then turn detergent valve off.
STEP 4: Open spray gun to relieve
remaining pressure.
CAUTION: Always store your pressure
washer in a location where the tempera-
ture will not fall below 32°F (0°C). The
pump in this machine is susceptible to
permanent damage if frozen. FREEZE DAMAGE IS
NOT COVERED BY WARRANTY.
1. Stop the pressure washer, squeeze spray gun
trigger to release pressure.
2. Detach water supply hose and high pressure
hose.
3. Turn on the machine for a few seconds, until
remaining water exits. Turn engine off immediately.
4. Drain the gas and oil from the engine.
5. D o n o t a l l o w h i g h p r e s s u r e h o s e t o
become kinked.
6. Store the machine and accessories in a room which
does not reach freezing temperatures.
10

SHUTDOWN INSTRUCTIONS

Burner
Switch
Pump
Switch
STEP 2: Push burner switch off
and pull spray gun allowing water
to flow which will cool down the
heating coil.
After water has cooled, release the
trigger on the spray gun which will
activate a timer to shut the machine
off after one minute. Turn the pump
switch off if the machine is going to
be left unattended.

STORAGE

LANDA SEHW • 8.913-932.0 • Rev. 02/12a
Temp.
Control
Knob
STEP 3: Turn water off and remove
water supply hose.
After Extended Storage
CAUTION: Prior to restarting, thaw out any
possible ice from pressure washer hoses,
spray gun or wand.