Hot water - diesel powered - diesel/oil heated (44 pages)
Summary of Contents for Landa PGHW4-3000
Page 1
PGHW OPERATOR’S MANUAL ■ PGHW4-3000 ■ PGHW4-4000 ■ PGHW5-3000 ■ PGHW5-3500 1.110-048.0 1.110-047.0 1.110-046.0 1.110-045.0 l fo af et X XX X XX X XX 8916485-1 For technical assistance or the dealer nearest you, consult our web page at www.landa.com...
The model and serial numbers will be found on a decal attached to the pressure washer. You should record both serial number and date of purchase and keep in a safe place for future reference. 8.916-485.0 • LANDA PGHW • REV. 5/12...
KEEP WATER fuel should the equipment be exposed to a SPRAY AWAY FROM utility company or the selling ELECTRICAL WIRING. higher ambient temperature. distributor for specific details. 8.916-485.0 • LANDA PGHW • REV. 5/12...
Failure to do this could LADDER. result in injury from a whipping wand. 14. Never make adjustments on machine while in operation. TRIGGER GUN KICKS BACK - HOLD WITH BOTH HANDS 8.916-485.0 • LANDA PGHW • REV. 5/12...
28. In oil burning models, use only kerosene, No. 1 home heating fuel, or diesel. If diesel is used, add a soot remover to every tankful. Follow the maintenance instructions specified in the manual. 8.916-485.0 • LANDA PGHW • REV. 5/12...
KEEP OUT OF THE REACH OF CHILDREN. DO NOT TIP. KEEP VENT CAPS TIGHT AND LEVEL. Volt Group 24 bat- tery is recommended for placement within the weather Red + Positive Terminal resistant box. Follow safety and installation instructions furnished with the battery. 8916485-30 8.916-485.0 • LANDA PGHW • REV. 5/12...
Variable pressure control wand handle must be turned clockwise to enable water to flow out of the high pressure nozzle. To apply detergent, place detergent pick-up tube into a container of detergent and turn the detergent valve counterclockwise. 8.916-485.0 • LANDA PGHW • REV. 5/12...
When the water reaches this temperature, the pump protector engages and cools the pump by discharging the warm water onto the ground. This thermal device prevents internal damage to the pump. 8.916-485.0 • LANDA PGHW • REV. 5/12...
3. Pour about one teaspoon of engine oil through engine manufacturer’s manual for service and mainte- spark plug hole, pull starter grip several times and nance of the engine. replace the plug. Then pull the starter grip slowly 8.916-485.0 • LANDA PGHW • REV. 5/12...
Faulty burner transformer Test transformer for proper arc between contacts. Replace as needed. (continued on Disconnected or short in electrical All wire contacts should be clean and tight. No next page) wiring breaks in wire 8.916-485.0 • LANDA PGHW • REV. 5/12...
Page 12
Remove coils and burner assembly, clean and burner assembly thoroughly. Misaligned electrode setting Realign electrodes to specifications. Obstruction in smoke stack Check for insulation blockage or other foreign objects. Low engine RPM Increase RPM 8.916-485.0 • LANDA PGHW • REV. 5/12...
Page 13
O-Ring plunger retainer worn Check and replace if necessary. Cracked piston Check and replace if necessary. Pump protector Lower water supply pressure. Do not run with spray gun closed longer than 2 minutes. 8.916-485.0 • LANDA PGHW • REV. 5/12...
Position correctly, tighten set screw. Defective control switch Replace switch. Loose wire Check and replace or tighten wiring. Defective burner motor Replace motor. RELIEF VALVE Relief valve defective Replace or repair. LEAKS WATER 8.916-485.0 • LANDA PGHW • REV. 5/12...
Check air inlet to make sure it is not clogged extreme problem, periodic use of Landa Deliming Pow- or blocked. Wipe off any oil spills and keep equipment der (Landa Part #9-028008) will remove lime and other clean and dry. deposits before coil becomes plugged. (See Deliming instructions for use of Landa Deliming Powder.)
Do not exceed 200 psi. NOTE: When changing fuel pump, a bypass plug must be installed in return port or fuel pump will not prime. Air Shutter Air Band Locking Screw Locking Screw 8.916-485.0 • LANDA PGHW • REV. 5/12...
NOTE: If a flue is installed, have a professional serviceman adjust your burner for a #1 or #2 smoke spot on the Bacharach scale. 8.916-485.0 • LANDA PGHW • REV. 5/12...
3 months or 500 hours thereafter. Use SAE 30 weight oil, non-detergent. Date Oil Changed No. of Operating Hours Brand Name and Month/Day/Year Since Last Oil Change Type of Oil (See above) 8.916-485.0 • LANDA PGHW • REV. 5/12...
LANDA SURE FIRE BURNER REPLACEMENT PARTS For best performance specify genuine Sure Fire replacement parts 8.916-485.0 • LANDA PGHW • REV. 5/12...
Page 33
LANDA SURE FIRE BURNER REPLACEMENT PARTS For best performance specify genuine Sure Fire replacement parts 8.916-485.0 • LANDA PGHW • REV. 5/12...
O-Ring Ø2.62 x 17.13 9.803-177.0 Shim See Kit Valve Assembly 9.803-181.0 Bearing Housing See Kit O-Ring Ø2.62 x 20.29 See Kit Plunger Bolt 9.802-928.0 Valve Plug See Kit Copper Spacer 9.802-943.0 Manifold Stud Bolt 8.916-485.0 • LANDA PGHW • REV. 5/12...
Page 35
NUMBER OF CYLINDERS KIT WILL SERVICE REPAIR KIT 9.802-603.0 9.802-606.0 NUMBER Complete Valve Plunger Oil Seals KIT DESCRIPTION (all pumps) (all pumps) ITEM NUMBERS 14, 15, 16 INCLUDED NUMBER OF CYLINDERS KIT WILL SERVICE 8.916-485.0 • LANDA PGHW • REV. 5/12...
“spike” pressure exceeds the 500 psi limit, remove the adjusting knob (Item 18) and re-adjust (lower) the nuts (Items 15) on the stem (Item 8). Re-attach the adjusting knob (Item 18), then repeat step #6. 8.916-485.0 • LANDA PGHW • REV. 5/12...
Page 37
Authorized LANDA Dealer of the defect. Your Authorized LANDA Dealer will file a claim with Landa, who must subsequently verify the defect. In most cases, the part must be returned to LANDA freight prepaid with the claim. For warranty service on components warranted by other manufacturer’s, your Authorized LANDA Dealer can help you obtain warranty service through these manufacturers’...
Page 38
Form #8.916-485.0 • Revised 5/12 • Printed in U.S.A.