Link Performance Monitoring; Miscellaneous Link Message Support; Module Status Indicators; Table A-14. Module Led Status Indicators - Lucent Technologies CBX 500 Installation Manual

Multiservice wan switch hardware
Hide thumbs Also See for CBX 500:
Table of Contents

Advertisement

IOP and IOA Module Specifications
8-port Subrate Module

Clocking Options

Loop timing
Internal timing (better than Stratum 4 - +/- 20 PPM [pulse position modulation])
External timing via 1.544 MHz T1 source

Link Performance Monitoring

DS3 MIB (RFC 1407) near-end statistics
User-configurable thresholds for DS3 performance parameters

Miscellaneous Link Message Support

Application identification channel signal (identifies link as M13 or C-bit parity
mode)
Recognition and generation of far-end block error (FEBE) events in C-bit parity
mode

Module Status Indicators

Table A-14. Module LED Status Indicators

LED State
Good LED lit
Failed LED lit
Redundant LED lit
Good and Failed LEDs
blinking simultaneously
A-424/5/03
Beta Draft Confidential
Normal operation
Module failure
Redundant module online
OS software image currently being downloaded
from active switch processor (SP)