Casio QT-6600 Service Manual page 65

Electronic cash register
Hide thumbs Also See for QT-6600:
Table of Contents

Advertisement

[ 20 ] REMOTE DISPLAY Test:
[Function]
Tests whether the data is correctly displayed on REMOTE DISPLAY.
Be sure to connect REMOTE DISPLAY to COM3. When changing the baud rate, be sure to also
change the settings on REMOTE DISPLAY. The backlight turns on in pastel green (green + white)
when performing the test and turns off when the test ends.
When performing a single test:
In order to complete the test, the operator must determine pass(OK)/fail(NG) of the result.
After the operator determines pass(OK)/fail(NG), the display and the backlight turn off.
When repeating the test infinitely:
Repeats transmitting the same test text at a set interval.
Press [ESC] to terminate the test, clear the display, and turn off the backlight.
[Operation]
Operation : b
b:Specifying the baud rate
0
19.2 Kbps
1
9600 bps
n: Number of times
0 or no value
A value other than 0 (1 ~ 9) Tests repeat infinitely (press ESC to terminate)
[LCD]
REMOTE DISP
Please Hit Key
REMOTE DISP
END
[PRINT]
REMOTE DISP
REMOTE DISP
END
n
0
2
3
ST
To perform a single test
bn023
OK−>1 NG−>9
OK
bn023
bn023
OK
bn023
— 62 —
[REMOTE DISPLAY]
ABCDEFGHIJKLMNOP
QRSTUVWXYZabcdef
0,1,2,3,4,5,6,7,8,9,