9.2.1. Overview Errors Displayed
Display
Display
Error
on
by
Name
Screen
END LED
2Hz / 5sec. Pause
EDW 1500 EDW1100
1 x
Water tap closed
flashing
2 x
Drain pump
flashing
3 x
Aqua-Control
flashing
Recycling pump
5 x
Triac short-circuit
flashing
6 x
Heating
flashing
7 x
NTC Sensor
flashing
8 x
EEPROM
flashing
Check sum
9 x
MCF / CCF
flashing
10 x
Sprayarm blocked
flashing
11 x
Turpidity sensor
flashing
Communication
12 x
error
flashing
13 x
Tacho
flashing
14 x
Filling time error
flashing
D GN-TDS-N
Error Display
Call
Acoustic
visible for
Error Memory
Indication
Customer**
(Service)
No.of Beeps
Display
Display
2Hz / 5sec. Pause
AK
AK
PAA
PAA
If available for
this model
J
J
J
J
1 x
J
J
J
J
2 x
J
J
J
J
3 x
J
J
J
5 x
J
J
6 x
J
J
7 x
J ?
8 x
J
J
9 x
J
J
J
10 x
J
J
11 x
J
J
12 x
J
J
13 x
J
J
14 x
**
= If 7-Segment display available, no PAA error display/Sound error display generally with VGA, with other machines depending on model
Applicable for EDW1500 / 1503 (VGA) -- EDW1100 / 1003 (VGA) -- EDW2000
Output via
Short Explanation
Indicator Lamp
If available for
this model
Switchpoint of pressostat is not reached
LED Water
after max. 60 secs.
(only in programme steps incl. Filling up to level!)
Reset point of pressostat is not reached after max. 120secs.
---
Programme stop.
---
Aqua-Control System switches off solenoid directly.
Tacho signals are recognized although rec. pump is not
---
During heating, temperature rise by min. 1.5K is not detected
---
---
NTC short-circuit or break.
---
Communication error with ext. EEPROM
Check sum (model programming) MCF or Check sum CCF
---
Only recognized after switching on!
At programme start and each subprogramme start,
also after door open/close or mains failure, spray arm
LED Spray arm
is checked and evaluated.
The turbidity signal required for calibration
---
is not reached with 15secs.
---
Communication failure with User Interface.
Recycling pump selected, but no tacho signal
---
recognized for 5 + 20 secs
---
Time limit during filling exceeded
Programme stops and can be continued after error remedy by
pressing the programme key. If fault is not corrected and programme
key is pressed, the machine runs dry until next subprogramme.
Programme stops and can be continued after error remedy
by pressing the programme key.
Programme stops and restarts automatically when error has
Programme stops and water is filled up until reset point of
selected.
Programme is continued until its end without heating function!
within 3min.
Programme is continued until its end without heating function!
Programme selection not possible.
not OK.
Error display until sprayarm speed is recognized,
rotation
Programme sequence is adapted accordingly.
Machine stops, waiting until communication is cleared.
Recycling pump without control, heating off.
This function is checked again on each step.
Programme is completed until next subprogramme without
level. No further filling up of water top up. Error is reset after
What happens?
terminated.
pressostat
On/Off LED is on
or if no control.
Always recognition of turbidity.
one complete drain cycle.