8.4.2. Service menu / Error code and actuator test
1.
2.
OK / START
OK / START
OK / START
3.
OK / START
OK / START
4.
RESET
oder automatisch nach 60sek.
Ä The error memory can be read out by pressing the Ok/Start button.
2.
Ä
Ä The error descriptions are explained in chapter 21.
Ausgabe Fehler 1
Ä
Ä The actuator test is activated the next time the Ok/Start button is pressed.
3.
Ausgabe Fehler 2
Ä
Ä With each additional push of the button, the next stage is called up as follows.
Ausgabe Fehler 3
Ä
4. Leaving the function
"1 ALARM CODE" appears in the display text line and the coded error is
displayed next to the "i" . (Iin the example only red fields)
An additional 2 errors can be read out the next two times the
Ok/Start button is pressed.
"2 ACTUATORS " appears in the display text line and the actuator which is
triggered is indicated with a number.
2 AKTUATORS 4
Triggering of the regeneration valve
Triggering of the drain pump
2 AKTUATORS 5
Triggering of the inlet valve
2 AKTUATORS 6
(Filling to the level - should the level already exist do not fill)
2 AKTUATORS 7
Triggering of the heater element
(Only carried out when the level is detected)
2 AKTUATORS 8
Triggering of the circulation pump
2 AKTUATORS 9
Triggering of the detergent dispenser
Triggering of the dryer ventilation
2 AKTUATORS 10
Triggering of the autodosage
2 AKTUATORS 11
2 AKTUATORS 12
Triggering of the water hardness sensor
All 3 error memories and the complete actuator test can be called up
any number of times by scrolling.
By pressing the Reset button, the function is quitted and "SELECT
PROGRAM" appears in the text field of the display
or this occurs should no button be pressed within 60 seconds
- or the dishwasher is deactived with the On/Off button.
currently unused
currently unused
-