Packtrack - Datalogic DS8100A Reference Manual

Hide thumbs Also See for DS8100A:
Table of Contents

Advertisement

9
The
decoder
will
+  max and -  max as shown in the following figure:
The formulas to calculate  maximum depend on various parameters such as: label height,
number of scans per second, code motion speed, etc. Minimum label heights at different
conveyor speeds are given in the tables in par. 9.3.1, depending on standard  values of 45°
and 30°.

9.2 PACKTRACK™

PackTrack™ is a patented operating mode for Datalogic Omni-Directional Reading Stations
used to read and correctly assign codes read on different packs when placed in the scanner
Reading Area at the same time.
In fact, in the following example, the codes of two or more consecutive packs are found at
the same time in the scanner reading area. Therefore, the condition occurs where, in the
sequence of the two packs, the code of the second pack is read first, just before the code of
the previous pack. A system without PackTrack™ would assign the code of the second pack
to first pack and vice versa, thus causing a gross error in sortation.
Working in PackTrack™ mode requires the presence of an encoder and a presence sensor
to track the moving packs.
74
be
able
to
read
OK
No Read
No Read
Figure 88 – Reading Zones with  Max
Figure 89 – PackTrack™ System Layout
DS8100A REFERENCE MANUAL
the
label
with
0
°
OK
OK
Conveyor
-
+
No Read
OK
OK
Laser Beam
a
tilt
angle
between

Advertisement

Table of Contents
loading

Table of Contents