Datalogic DS8100A Reference Manual page 36

Hide thumbs Also See for DS8100A:
Table of Contents

Advertisement

3
The driving logic of the input signals may be powered, for convenience, with the voltage
supply at the CBX terminal block spring clamps (V+) and (V-). In this case, however, the
device is no longer electrically isolated. The voltage available on pins V+ and V-, is physically
the same as the input power for the scanner (Vdc and GND).
INPUT 1 (EXTERNAL TRIGGER/PS) CONNECTIONS USING DS8100A POWER
Figure 21 – MEP-593 PH-1 (PNP) External Trigger/PS Using DS8100A Power
INPUT 1 (EXTERNAL TRIGGER/PS) CONNECTIONS USING EXTERNAL POWER
Figure 23 - PNP External Trigger/PS Using External Power (i.e. PLC signal)
Figure 24 - NPN External Trigger/PS Using External Power (i.e. PLC signal)
22
MEP-593 PH-1 Ph oto cell (PNP)
NPN Photocell
Figure 22 - NPN External Trigger/PS Using DS8100A Power
DS8100A REFERENCE MANUAL
( brown)
(b lack)
(b lue)
Power to
In put
Photocell
Signal
Photoce ll
Reference
Input
Signal
External Device
Ground Refe rence
External D evice
Power Ref erence
Input
Signal