Datalogic DS8100A Reference Manual page 66

Hide thumbs Also See for DS8100A:
Table of Contents

Advertisement

7
Figure 71 – Example Large Synchronized Network Reading Station
Here are a few helpful hints which can improve station performance and reduce installation
time:
1. Scanner distribution should alternate between odd and even branches so that the
station guarantees 50% reading on all sides. See also Figure 70.
2. For OEK Encoders set the parameter Operating Mode>Encoder Step = 248.
3. For Top Front and Top Back scanners (C and D in Figure 71), set the parameter
Reading Parameters>Reading Condition = Skew 45°.
4. For applications having regular shaped packs the default settings are sufficient, but
for Airport applications, irregular shaped packs can cause PS signal glitches resulting
in false "packs too short" or "packs too close" errors.
To correct this, set the following Operating Modes parameters:
Between Packs = 200 mm, Minimum Pack Length = 200 mm, Window Dimension = 200 mm
52
E
C
F
G
Conveyor
OFF
ON
1 2 3 4 5 6 7 8
DS8100A REFERENCE MANUAL
D
B
SC6000
H
A
PWO
Minimum Distance
.

Advertisement