Code Verifier; Outputs - Datalogic DS8100A Reference Manual

Hide thumbs Also See for DS8100A:
Table of Contents

Advertisement

CUSTOM CABLE ELECTRICAL CONNECTIONS
INPUT 3 - 4 CONNECTIONS USING EXTERNAL POWER

4.4.1 Code Verifier

If the DS8100A is used as a Code Verifier, the verifier code can be configured in software
through the Genius™ configuration program. However it is also possible to use one of the
inputs to trigger when the scanner should store a code read as the verifier code.
The Code Verifier parameter must be enabled, and the configuration parameters to allow
correct Code Type reading must be saved to the scanner in order to read the verifier code.
When the selected input is activated, the next read code will be stored as the verifier code in
the scanner's non-volatile (Flash) memory.
For more details see the Verifier Parameters in the "6-8 K Software Configuration Parameter
Guide" or Help file.

4.5 OUTPUTS

Three general purpose outputs are available. The electrical features are given below:
Outputs 1 and 2
Maximum Voltage
Collector Current (pulse)
Collector Current (continuous)
Saturation Voltage (VCE)
Maximum Power Dissipation
DS8100A
+ 5V
~
-
+
~
+ 5V
~
-
+
~
Figure 54 - I3/I4 PNP Input Command using External Power
30 V
130 mA Max.
40 mA Max.
1 V at 10 mA Max.
90 mW at 50°C (Ambient temperature)
Vext
EXTERNAL DEVICE
V
I3A
Grou nd
Vext
V
I4A
I34B
Grou nd
4
39

Advertisement

Table of Contents
loading

Table of Contents