Lonworks Interface - Datalogic DS8100A Reference Manual

Hide thumbs Also See for DS8100A:
Table of Contents

Advertisement

5

5.2 LONWORKS INTERFACE

The Lonworks network is used for both input and output connection to build a multi-sided or
omni-station system connecting several readers.
The DS8100A master usually employs the 17-pin female connector for output connection to
the first slave, while the 17-pin male connector is terminated by inserting the BTK-8102
terminator (see Figure 58 for details).
Both connectors are always employed when connecting together the slave readers. In
particular, the 17-pin female connector is used for output connection and the male one for
input connection. The female connector in the last slave reader is terminated by the
BTK-8100 bus return to close the system network.
The following diagram represents the connection between a DS8100A working as master
and a DS8100A working as a slave reader.
The cable shields for LON A/B are connected to pin1 and pin 3 - CHASSIS.
44
Master
VS_I/O
12
13
REF_I/O
15
CHASSIS
1
LON A+
8
9
LON A-
10
LON B+
11
LON B-
CHASSIS
3
VS
A1
GND
A2
= male connector
= female connector
Figure 60 – DS8100A Master/Slave Lonworks Connection
DS8100A REFERENCE MANUAL
Slave
12
13
15
CHASSIS
1
8
9
10
11
CHASSIS
3
AWG 13
A1
A2
AWG 13

Advertisement

Table of Contents
loading

Table of Contents