Installation; Safety Precautions; Location; High Frequency Protection - Lincoln Electric LN-25 SVM179-B Service Manual

Wire feeder
Table of Contents

Advertisement

A-3

SAFETY PRECAUTIONS

WARNING
ELECTRIC SHOCK CAN KILL.
• Turn the input power OFF at the
disconnect switch or fuse box
before attempting to connect or
disconnect input power lines, out-
put cables or control cables.
• Only qualified personnel should
perform this installation.
• Do not touch metal portions of the LN-25™ PRO
work clip when the welding power source is on.
• Do not attach the work clip to the wire feeder.
• Connect the work clip directly to the work, as
close as possible to the welding arc.
• Turn power off at the welding power source
before disconnecting the work clip from the
work.
• Only use on power sources with open circuit
voltages less than 110 VDC.
------------------------------------------------------------------------

LOCATION

For best wire feeding performance, place the LN-
25™ PRO on a stable and dry surface.
wire feeder in a vertical position. Do not operate the
wire feeder on an angled surface of more than 15
degrees.
Do not submerge the LN-25™ PRO.
RECOMMENDED CABLE SIzES (RUBBER COVERED COPPER - RATED 167°F or 75°C)**
AMPERES
PERCENT
DUTY
CYCLE
200
60
200
100
225
20
225
40 & 30
250
30
250
40
250
60
250
100
300
60
325
100
350
60
400
60
400
100
500
60
** Tabled values are for operation at ambient temperatures of 104°F(40°C) and below. Applications above 104°F(40°C) may require cables
larger than recommended, or cables rated higher than 167°F(75°C).

INSTALLATION

Keep the
TABLE A.1
CABLE SIZES FOR COMBINED LENGTHS OF ELECTRODE AND WORK CABLES
0 to 50Ft.
50 to 100Ft.
(0 to15m)
(15 to 30m)
2
2
4 or 5
3
3
2
1
1
1
2/0
2/0
1/0
1/0
2/0
2/0
3/0
3/0
2/0
2/0
LN-25™ PRO
The LN-25™ PRO is rated IP23 and is suitable for
outdoor use.
The handle of the LN-25™ PRO is intended for
moving the wire feeder about the work place only.
When suspending a wire feeder, insulate the
hanging device from the wire feeder enclosure.

HIGH FREQUENCY PROTECTION

Locate the LN-25™ PRO away from radio controlled
machinery. The normal operation of the LN-25™
PRO may adversely affect the operation of RF con-
trolled equipment, which may result in bodily injury
or damage to the equipment.
--------------------------------------------------------------------------

WELD CABLE SIzE

Table A.1 Located below are copper cable sizes rec-
ommended for various currents and duty cycles.
Lengths stipulated are the distance from the welder to
work and back to the welder again. Cable sizes are
increased for greater lengths primarily for the purpose
of minimizing voltage drop in the cables.
100 to 150 Ft.
(30 to 46m)
2
2
2
2
3
2
3
2
3
2
2
1
1
1
1
1
1
1
2/0
2/0
2/0
3/0
3/0
CAUTION
150 to 200 Ft.
200 to 250 Ft.
(46 to 61m)
(61 to 76m)
1
1/0
1
1/0
1
1/0
1
1/0
1
1/0
1
1/0
1
1/0
1
1/0
1/0
2/0
2/0
3/0
2/0
3/0
3/0
4/0
3/0
4/0
3/0
4/0
A-3