Lincoln Electric LN-25 SVM179-B Service Manual page 8

Wire feeder
Table of Contents

Advertisement

A-2
TECHNICAL SPECIFICATIONS – LN-25™ PRO (K2613-1, -2, -5, and -7)
(24-42 VAC with remote voltage control kit installed)
DUTY CYCLE
60% rating
100% rating
GEARING - WIRE FEED SPEED RANGE-WIRE SIzE
GEARING
Extra torque
K2613-2 & K2613-7
Normal Speed
K2613-1 & K2613-5
HEIGHT
14.8 Inches
(376 mm)
Handle folded down
OPERATION:
STORAGE:
INSTALLATION
INPUT VOLTAGE and CURRENT
INPUT VOLTAGE ± 10%
15-110 VDC
RATED OUTPUT @ 104°F (40°C)
GMAW
WFS RANGE
WIRE SIzES
.023 – 1/16"
50 – 400 ipm
(0.8 – 10.1m/min)
(0.6 – 1.6mm)
50 – 700 ipm
.023 – 1/16"
(1.3 – 17.7m/min)
(0.6 – 1.6mm)
PHYSICAL DIMENSIONS
WIDTH
8.7 Inches
(221 mm)
TEMPERATURE RANGE
-40°F to 104°F (-40°C to 40°C)
-40°F to 185°F (-40°C to 85°C)
LN-25™ PRO
INPUT AMPERES
INPUT AMPERES
450
325
FCAW
WFS RANGE
WIRE SIzES
30 – 400 ipm
(0.8 – 10.1m/min)
(10.3 – 2.4mm)
50 – 700 ipm
(1.3 – 17.7m/min)
(0.8 - 2.0mm)
DEPTH
22.2 Inches
(589 mm)
A-2
4A
.030 - 3/32"
.030 - 5/64
WEIGHT
36 lbs
(16 kg)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ln-25 pro

Table of Contents