Lincoln Electric LN-25 SVM179-B Service Manual page 13

Wire feeder
Table of Contents

Advertisement

A-7
POWER SOURCE TO LN-25™ PRO
CABLE CONNECTION DIAGRAMS
ACROSS THE ARC SET-UPS
CC Power Sources with Output Terminals Always
Hot (See Figure A.5)
CC Power Source
Ranger 250, 250 LPG
Ranger 305G, 305D
Commander 300
Vantage 300, 400, 500
Air Vantage 500
Ranger 10,000
Ranger 3 phase
SAE 400 with CV adapter
Engine Driven welder with
Wire Feed Module
If the power source has a Remote/Local switch, place
the switch in the Local position.
Place the Power Source CC/CV switch (if present) or
Range Switch in the CV position if possible.
Set the CV/CC switch in the feeder to match the power
source.
CV
Power Sources with Stud Connectors and
Remote/Local Switch (See Figure A.6)
CV-655
CV-400
DC-400
DC-600
DC-655
V450-Pro
Place the power source Remote/Local switch in the
Local position.
Place CV/CC switch in the feeder in the "CV" position.
INSTALLATION
FIGURE A.5
Electrode
Work
KP1695-XX
KP1696-XX
KP1697-XX
See Magnum Literature
FIGURE A.6
Electrode
Work
KP1695-XX
KP1696-XX
KP1697-XX
See magnum Literature
LN-25™ PRO
LN-25 PRO
(Across the Arc)
Work clip
K#
K2613-1
LN-25™ PRO Wire Feeder
K2613-2
LN-25™ PRO Extra Torque
CC power Source
K1803-1
Welding Cables
LN-25 PRO
(Across the Arc)
Work clip
K#
K2613-1
LN-25™ PRO Wire Feeder
K2613-2
LN-25™ PRO Extra Torque
CV power Source
K1803-1
Welding Cables
A-7
Description
Drive Roll Kit
Welding Gun
Description
Drive Roll Kit
Welding Gun

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ln-25 pro

Table of Contents