Installation; Safety Precautions - Lincoln Electric IDEALARC DC-600 Service Manual

Hide thumbs Also See for IDEALARC DC-600:
Table of Contents

Advertisement

A-3
Read entire Installation Section before installing
the IDEALARC DC-600.

SAFETY PRECAUTIONS

WARNING
ELECTRIC SHOCK CAN KILL.
Only qualified personnel should install
this machine.
Turn the input power OFF at the
disconnect switch or fuse box before
working on the equipment.
Do not touch electrically hot parts.
Always connect the IDEALARC
DC-600 grounding terminal to a good
electrical earth ground.
Set the IDEALARC DC-600 Power ON/OFF PUSH BUTTON to
OFF position when connecting power cord to input power.
__________________
SELECT PROPER LOCATION
Place the IDEALARC DC-600 where clean air can
freely circulate in through the front intake and out
through the rear louvers. Dirt, dust, or any foreign
material that can be drawn into the machine should be
kept at a minimum. Not following these precautions
can result in the nuisance shutdown of the machine
because of excessive operating temperatures.
STACKING
Three IDEALARC DC-600 machines can be stacked.
DO NOT stack more than three machines in one
grouping.

INSTALLATION

DO NOT stack the IDEALARC DC-600 on another type
of machine.
Follow these guidelines when stacking:
1. Select a firm, level surface capable of sup-
porting
machines (1570 pounds/712 kilograms).
2. Set the bottom machine in place.
3. Stack the second machine on top of it by
aligning the two holes in the base rails of the
second machine with the two pins on top front
of the bottom machine.
4. Repeat process for third machine.
NOTE: The machines must be stacked with the Case
Front of each machine flush with each other.
See Figure A.1.
Stacking IDEALARC DC-600 machines
TILTING
The IDEALARC DC-600 must be placed on a
stable, level surface so it will not topple over.
IDEALARC
®
DC-600
the
total
weight
of
up
FIGURE A.1
STACKING HOLE
STACKING PINS
A-3