Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation could cause an unexpected fault. Before installing this equipment read this manual carefully. Please provide this manual to the owner of the equipment for future use. The Warning symbol indicates the presence of dangerous voltage within and outside the product enclosure that may constitute a risk of electric shock, serious injury or death to persons if proper precautions are not followed.
Installing a R-Series IP or Analog Analytic Module Installing the Optional R-Series Rack-Mount Shelf Positioning and Selecting Camera Locations Connecting to External Devices Troubleshooting Performing a Factory Reset on the Rialto™ I4 and A4 Analytic Appliances Replacing a Hard Drive on the Rialto™ R-Series Analytic Appliances...
IP Address: 169.254.238.51 Subnet Mask: 255.255.0.0 Installation The Rialto™ analytic appliances include the R-Series analytic appliance, the A4 analytic appliance, and the I4 analytic appliance. Determine which device you are installing and complete the relevant procedures. Rialto™ I4 Analytic Appliance Rialto™...
Front View of the I4 Analytic Appliance 1. Audio Connector 1 Provides 1 audio input and 1 audio output. Use the audio splitter cable to connect microphones and powered speakers. 2. Serial I/O Connector Provides a connection for 4 alarm inputs and 5 alarm outputs, RS-485 and RS-232 data communication, and 12V DC power.
Used for network communications. Connecting an IP Camera to an I4 Analytic Appliance You can connect IP cameras to the Rialto I4 analytic appliance through the network. You do not need to physically connect IP cameras to the analytic appliance. To do this, you will need:...
3. Connect the power supply. Connecting an Analog PTZ Camera to an A4 Analytic Appliance You can also connect PTZ cameras to the Rialto A4 analytic appliance. NOTE: The analytic appliance only supports PTZ cameras that use Pelco P and Pelco D communication protocols.
Page 12
Up to 4 PTZ cameras can be connected in series to the analytic appliance with unique Pelco protocol addresses. Once the PTZ camera is connected, you can configure it in the Avigilon™ View Software. NOTE: The PTZ camera's Pelco protocal address must correspond to the analytic appliance channel it's attached to.
Rialto™ R-Series Analytic Appliance Back View of the R-Series Analytic Appliance 1. Rack-Mount Analytic Appliance Supports up to 4 analytic modules for connecting analog or IP cameras. 2. Analog Analytic Module Supports up to 4 analog cameras per unit. 3. IP Analytic Module Supports up to 4 SD, 3 720p, or 2 HD cameras.
Front View of the R-Series Analytic Appliance 1. 10/100 Ethernet Port Used as a maintenance port. 2. Disk Power LED Shows when the disk has power. 3. Disk Activity LED Shows when the hard disk drive is written to or read from. 4.
5. Screw the module into place. Installing the Optional R-Series Rack-Mount Shelf The Rialto™ R-Series analytic appliance can be installed onto a standard IU rack using the R-Series rack-mount shelf. The optional shelf is designed to leave the analytic appliance vents free for proper air flow.
Page 16
Figure 3: (1) rack posts (2) shelf 3. From the front of the rack, slide the back of the analytic appliance onto the shelf until the face is flush with the front posts. Installing the Optional R-Series Rack-Mount Shelf...
Page 17
4. Ensure the analytic appliance vents extend beyond the shelf to allow for adequate cooling. 5. Use the remaining mounting screws to secure the front of the analytic appliance to the posts of the server rack. Installing the Optional R-Series Rack-Mount Shelf...
The choice of camera location can impact the quality of the analytics results. For details about positioning and selecting camera locations, see Designing a Site for Video Analytics. The document is available in the eDocs app and on the Avigilon website. Positioning and Selecting Camera Locations...
Connecting to External Devices External devices are connected to the device through the I/O terminal. The Rialto A4, I4 and R-Series appliance have the same I/O terminal. The pinout for the I/O terminal is shown in the following diagram: 1. 12 V optional power input for the analytic appliance 2.
Page 20
9. ** — Switch 10. *** — RBSNTTL or similar relay module Connecting to External Devices...
Troubleshooting Performing a Factory Reset on the Rialto™ I4 and A4 Analytic Appliances A factory reset will reset the analytic appliance back to its default factory settings. You do not need to power down the analytic appliance before performing a factory reset.
Page 22
Only format the drive if no data has been preserved. If you need to format the hard drive or want to check the type of drive you're using, you can do so using the Avigilon™ View software.